Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
456
matching recommendationsSIC | 35 | Industrial Machinery And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0263 # 04 Y:2003 | 04 | 2003 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $47,210 | $100,000 | Implemented |
NC0263 # 05 Y:2003 | 05 | 2003 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $8,768 | $10,000 | Not Implemented |
NC0263 # 06 Y:2003 | 06 | 2003 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $46,271 | $135,400 | Not Implemented |
NC0263 # 07 Y:2003 | 07 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $556 | $680 | Implemented |
NC0263 # 08 Y:2003 | 08 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $413 | $240 | Implemented |
NC0237 # 01 Y:2002 | 01 | 2002 | RECYCLE WHITE WATER | $6,970 | $3,500 | Implemented |
NC0237 # 02 Y:2002 | 02 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,443 | $680 | Implemented |
NC0237 # 03 Y:2002 | 03 | 2002 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,935 | $3,000 | Not Implemented |
NC0237 # 04 Y:2002 | 04 | 2002 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,825 | $500 | Not Implemented |
NC0216 # 01 Y:2001 | 01 | 2001 | AVOID REWINDING MOTORS MORE THAN TWICE | $902 | $662 | Implemented |
NC0216 # 02 Y:2001 | 02 | 2001 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,475 | $1,464 | Not Implemented |
NC0216 # 03 Y:2001 | 03 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $340 | $608 | Not Implemented |
NC0216 # 04 Y:2001 | 04 | 2001 | INSULATE BARE EQUIPMENT | $1,799 | $549 | Implemented |
NC0216 # 05 Y:2001 | 05 | 2001 | UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING | $9,998 | $40,000 | Implemented |
NC0216 # 06 Y:2001 | 06 | 2001 | UTILIZE OTHER METHODS TO REMOVE CONTAMINANTS | $50,246 | $30,000 | Not Implemented |
NC0216 # 07 Y:2001 | 07 | 2001 | INSTALL EQUIPMENT TO MOVE PRODUCT | $130,124 | $27,500 | Not Implemented |
NC0199 # 01 Y:2000 | 01 | 2000 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $1,845 | $777 | Not Implemented |
NC0199 # 02 Y:2000 | 02 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,374 | $7,490 | Implemented |
NC0199 # 03 Y:2000 | 03 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,516 | $1,070 | Not Implemented |
NC0199 # 04 Y:2000 | 04 | 2000 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $351 | $102 | Not Implemented |
NC0199 # 05 Y:2000 | 05 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,352 | $210 | Implemented |
NC0199 # 06 Y:2000 | 06 | 2000 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $5,140 | $0 | Implemented |
NC0199 # 07 Y:2000 | 07 | 2000 | INSTALL COMMON HEADER ON COMPRESSORS | $26,946 | $118,000 | Not Implemented |
TN0694 # 01 Y:2000 | 01 | 2000 | INITIATE A PROGRAM TO ACQUIRE ISO CERTIFICATION | $219,860 | $100,000 | Not Implemented |
TN0694 # 02 Y:2000 | 02 | 2000 | ADD AREA LIGHTING SWITCHES | $17,510 | $25,030 | Implemented |