Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,797
matching recommendationsSIC | 353 | Construction And Related Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0509 # 04 Y:2002 | 04 | 2002 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $610 | $1,920 | Not Implemented |
CO0509 # 05 Y:2002 | 05 | 2002 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $17,700 | $2,000 | Implemented |
CO0509 # 06 Y:2002 | 06 | 2002 | INCREASE USE OF AUTOMATION | $9,140 | $1,600 | Implemented |
CO0509 # 07 Y:2002 | 07 | 2002 | USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS | $2,450 | $1,330 | Implemented |
CO0509 # 01 Y:2002 | 01 | 2002 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $2,920 | $8,000 | Not Implemented |
CO0509 # 02 Y:2002 | 02 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,620 | $230 | Implemented |
CO0509 # 03 Y:2002 | 03 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $640 | $2,260 | Not Implemented |
LL0149 # 01 Y:2002 | 01 | 2002 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $1,932 | $1,499 | Implemented |
LL0149 # 02 Y:2002 | 02 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,591 | $210 | Not Implemented |
LL0149 # 03 Y:2002 | 03 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,237 | $0 | Not Implemented |
LL0149 # 04 Y:2002 | 04 | 2002 | INSTALL SKYLIGHTS | $1,206 | $1,660 | Implemented |
LL0149 # 05 Y:2002 | 05 | 2002 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $1,505 | $2,255 | Implemented |
UU0025 # 01 Y:2002 | 01 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,405 | $13,567 | Implemented |
UU0025 # 02 Y:2002 | 02 | 2002 | OPTIMIZE PLANT POWER FACTOR | $3,455 | $3,500 | Implemented |
UU0025 # 03 Y:2002 | 03 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,913 | $260 | Implemented |
UU0025 # 04 Y:2002 | 04 | 2002 | HEAT WATER DURING OFF-PEAK PERIODS AND STORE FOR LATER USE | $1,056 | $0 | Implemented |
UU0025 # 05 Y:2002 | 05 | 2002 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,177 | $1,760 | Implemented |
UU0025 # 06 Y:2002 | 06 | 2002 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $1,285 | $30 | Implemented |
UM0216 # 06 Y:2002 | 06 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,496 | $7,269 | Not Implemented |
UM0216 # 05 Y:2002 | 05 | 2002 | INSTALL OCCUPANCY SENSORS | $222 | $620 | Not Implemented |
UM0216 # 01 Y:2002 | 01 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,873 | $1,125 | Not Implemented |
UM0216 # 02 Y:2002 | 02 | 2002 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,100 | $500 | Not Implemented |
UM0216 # 03 Y:2002 | 03 | 2002 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,056 | $500 | Not Implemented |
UM0216 # 04 Y:2002 | 04 | 2002 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $1,000 | $2,000 | Not Implemented |
BD0211 # 01 Y:2002 | 01 | 2002 | USE RADIANT HEATER FOR SPOT HEATING | $20,195 | $31,000 | Implemented |