Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
382
matching recommendationsSIC | 3531 | Construction Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK1087 # 07 Y:2023 | 07 | 2023 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $5,468 | $72,450 | Implemented |
OK1087 # 06 Y:2023 | 06 | 2023 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,321 | $11,550 | Implemented |
OK1087 # 01 Y:2023 | 01 | 2023 | USE RADIANT HEATER FOR SPOT HEATING | $18,209 | $91,432 | Implemented |
OK1087 # 05 Y:2023 | 05 | 2023 | USE SOLAR HEAT TO MAKE ELECTRICTY | $71,142 | $168,192 | Implemented |
MZ0340 # 01 Y:2023 | 01 | 2023 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,529 | $720 | Implemented |
MZ0340 # 04 Y:2023 | 04 | 2023 | INSTALL OCCUPANCY SENSORS | $618 | $260 | Implemented |
MZ0340 # 02 Y:2023 | 02 | 2023 | MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT | $3,688 | $320 | Implemented |
MZ0340 # 08 Y:2023 | 08 | 2023 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $27,531 | $5,336 | Implemented |
OK1080 # 05 Y:2023 | 05 | 2023 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $21,682 | $4,810 | Implemented |
OK1080 # 03 Y:2023 | 03 | 2023 | ELIMINATE LEAKS IN COMBUSTIBLE GAS LINES | $21,187 | $25,000 | Implemented |
OK1080 # 06 Y:2023 | 06 | 2023 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $13,757 | $5,295 | Implemented |
OR0754 # 01 Y:2022 | 01 | 2022 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $4,871 | $2,675 | Implemented |
OR0754 # 02 Y:2022 | 02 | 2022 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $1,033 | $3,560 | Implemented |
WV0623 # 03 Y:2022 | 03 | 2022 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $51,704 | $257,600 | Implemented |
WV0623 # 14 Y:2022 | 14 | 2022 | DEVELOP A REPAIR/REPLACE POLICY | $1,356 | $2,300 | Implemented |
WV0623 # 15 Y:2022 | 15 | 2022 | UPGRADE CONTROLS ON COMPRESSORS | $1,341 | $4,835 | Implemented |
WV0623 # 10 Y:2022 | 10 | 2022 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,877 | $2,813 | Implemented |
WV0623 # 13 Y:2022 | 13 | 2022 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,487 | $990 | Implemented |
WV0623 # 11 Y:2022 | 11 | 2022 | UPGRADE CONTROLS ON COMPRESSORS | $1,756 | $299 | Implemented |
WV0623 # 12 Y:2022 | 12 | 2022 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,660 | $3,000 | Implemented |
WV0623 # 01 Y:2022 | 01 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $72,629 | $104,885 | Implemented |
WV0623 # 02 Y:2022 | 02 | 2022 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $61,441 | $127,733 | Implemented |
AM0848 # 03 Y:2022 | 03 | 2022 | INSTALL OCCUPANCY SENSORS | $889 | $1,568 | Implemented |
AM0848 # 04 Y:2022 | 04 | 2022 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $149 | $408 | Implemented |
AM0848 # 02 Y:2022 | 02 | 2022 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,821 | $1,000 | Implemented |