Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

121

matching recommendations
Reset
SIC 3531 Construction Machinery
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0903 # 06 Y:2015 06 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,717 $11,876 Not Implemented
OK0903 # 08 Y:2015 08 2015 RECOVER WASTE HEAT FROM EQUIPMENT $3,490 $2,440 Not Implemented
OK0903 # 09 Y:2015 09 2015 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,183 $950 Implemented
OK0903 # 10 Y:2015 10 2015 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $8,904 $10,062 Implemented
OK0903 # 11 Y:2015 11 2015 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $2,427 $2,112 Not Implemented
OK0903 # 12 Y:2015 12 2015 INSULATE BARE EQUIPMENT $195 $240 Not Implemented
OK0903 # 07 Y:2015 07 2015 INSTALL OCCUPANCY SENSORS $2,170 $8,887 Not Implemented
OK0714 # 06 Y:2005 06 2005 MODIFY PROCESS TO REDUCE MATERIAL USE/COST $70,215 $3,931 Not Implemented
OK0714 # 05 Y:2005 05 2005 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $10,600 $0 Implemented
OK0714 # 04 Y:2005 04 2005 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $8,299 $70 Implemented
OK0714 # 03 Y:2005 03 2005 USE COMPRESSOR AIR FILTERS $4,058 $920 Implemented
OK0714 # 02 Y:2005 02 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $56,721 $117,780 Implemented
OK0714 # 01 Y:2005 01 2005 USE POWER DURING OFF-PEAK PERIODS $1,866 $0 Not Implemented
OK0675 # 07 Y:2003 07 2003 RECOVER WASTE HEAT FROM EQUIPMENT $4,672 $2,173 Not Implemented
OK0675 # 01 Y:2003 01 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $274 $256 Implemented
OK0675 # 02 Y:2003 02 2003 INSTALL OCCUPANCY SENSORS $124 $231 Not Implemented
OK0675 # 03 Y:2003 03 2003 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $4,171 $2,000 Implemented
OK0675 # 04 Y:2003 04 2003 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $2,210 $2,000 Not Implemented
OK0675 # 05 Y:2003 05 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $565 $367 Implemented
OK0675 # 11 Y:2003 11 2003 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $668 $287 Not Implemented
OK0675 # 06 Y:2003 06 2003 OPTIMIZE PLANT POWER FACTOR $428 $2,730 Not Implemented
OK0675 # 10 Y:2003 10 2003 LOWER LIGHT FIXTURES IN HIGH CEILING AREAS $61,378 $3,000 Not Implemented
OK0675 # 08 Y:2003 08 2003 INSTALL SET-BACK TIMERS $1,993 $0 Not Implemented
OK0675 # 09 Y:2003 09 2003 UTILIZE A CENTRAL COOLANT SYSTEM FOR CLEANING AND REUSE OF METAL WORKING FLUID $14,350 $23,640 Not Implemented
OK0624 # 03 Y:2001 03 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,627 $240 Implemented