Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

370

matching recommendations
Reset
SIC 3533 Oil And Gas Field Machinery
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0422 # 06 Y:1993 06 1993 INSTALL / REPAIR INSULATION ON STEAM LINES $671 $866 Implemented
OK0422 # 01 Y:1993 01 1993 REPAIR OR REPLACE STEAM TRAPS $170,442 $0 Implemented
OK0422 # 02 Y:1993 02 1993 INCREASE AMOUNT OF CONDENSATE RETURNED $126,322 $90,000 Implemented
OK0422 # 03 Y:1993 03 1993 REPAIR OR REPLACE STEAM TRAPS $106,473 $4,025 Implemented
OK0422 # 04 Y:1993 04 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,188 $4,152 Implemented
OK0415 # 05 Y:1993 05 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $948 $1,079 Implemented
OK0415 # 04 Y:1993 04 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,725 $3,693 Implemented
OK0415 # 03 Y:1993 03 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,487 $11,785 Implemented
OK0415 # 02 Y:1993 02 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,357 $4,918 Implemented
AM0190 # 02 Y:1993 02 1993 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $1,375 $1,200 Implemented
AM0190 # 03 Y:1993 03 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,180 $540 Implemented
AM0190 # 05 Y:1993 05 1993 PAY UTILITY BILLS ON TIME $440 $0 Implemented
AM0186 # 02 Y:1993 02 1993 TURN OFF EQUIPMENT WHEN NOT IN USE $33,670 $0 Implemented
AM0186 # 05 Y:1993 05 1993 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $7,460 $0 Implemented
AM0174 # 02 Y:1993 02 1993 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $3,950 $0 Implemented
AM0174 # 03 Y:1993 03 1993 INSTALL FOSSIL FUEL MAKE-UP AIR UNIT $890 $460 Implemented
AM0174 # 04 Y:1993 04 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,720 $420 Implemented
AM0174 # 05 Y:1993 05 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,370 $0 Implemented
AM0170 # 02 Y:1993 02 1993 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $25,000 $0 Implemented
AM0170 # 03 Y:1993 03 1993 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $10,100 $0 Implemented
AM0170 # 07 Y:1993 07 1993 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $2,360 $0 Implemented
AM0170 # 08 Y:1993 08 1993 USE PHOTOCELL CONTROLS $1,155 $570 Implemented
AM0168 # 05 Y:1993 05 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,470 $420 Implemented
AM0168 # 06 Y:1993 06 1993 INSULATE BARE EQUIPMENT $990 $2,140 Implemented
AM0168 # 08 Y:1993 08 1993 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $530 $153 Implemented