Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

331

matching recommendations
Reset
SIC 3537 Industrial Trucks And Tractors
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AM0120 # 02 Y:1991 02 1991 TURN OFF EQUIPMENT WHEN NOT IN USE $7,950 $215 Not Implemented
AM0120 # 03 Y:1991 03 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,506 $0 Not Implemented
AM0120 # 04 Y:1991 04 1991 INSTALL SET-BACK TIMERS $1,250 $0 Not Implemented
AM0120 # 05 Y:1991 05 1991 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,050 $1,960 Not Implemented
AM0120 # 06 Y:1991 06 1991 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $650 $680 Not Implemented
AM0120 # 07 Y:1991 07 1991 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $640 $50 Not Implemented
AM0120 # 08 Y:1991 08 1991 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $290 $350 Not Implemented
AM0082 # 01 Y:1990 01 1990 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $6,080 $14,110 Implemented
AM0082 # 02 Y:1990 02 1990 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,360 $2,000 Implemented
AM0082 # 03 Y:1990 03 1990 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $3,730 $12,000 Not Implemented
AM0082 # 04 Y:1990 04 1990 RESCHEDULE AND REARRANGE MULTIPLE-SOURCE HEATING SYSTEMS $2,824 $2,150 Implemented
AM0082 # 05 Y:1990 05 1990 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,380 $0 Implemented
AM0082 # 06 Y:1990 06 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $206 $208 Implemented
AM0082 # 07 Y:1990 07 1990 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $620 $600 Implemented
TN0389 # 01 Y:1990 01 1990 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $8,045 $18,750 Implemented
TN0389 # 02 Y:1990 02 1990 CLOSE OFF UNNEEDED STEAM LINES $3,217 $0 Not Implemented
TN0389 # 03 Y:1990 03 1990 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,349 $0 Implemented
TN0389 # 04 Y:1990 04 1990 USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM $1,071 $2,350 Implemented
TN0389 # 05 Y:1990 05 1990 KEEP LAMPS AND REFLECTORS CLEAN $2,447 $7,125 Implemented
TN0389 # 06 Y:1990 06 1990 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,258 $600 Implemented
TN0389 # 07 Y:1990 07 1990 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,227 $690 Implemented
KU0254 # 01 Y:1988 01 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,185 $2,000 Implemented
KU0254 # 02 Y:1988 02 1988 INSTALL TIMERS AND/OR THERMOSTATS $191 $0 Not Implemented
KU0254 # 03 Y:1988 03 1988 USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD $1,539 $0 Implemented
KU0254 # 04 Y:1988 04 1988 REPLACE BROKEN WINDOWS AND/OR WINDOW SASH $1,773 $1,800 Not Implemented