Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
928
matching recommendationsSIC | 354 | Metalworking Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0199 # 05 Y:2000 | 05 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,352 | $210 | Implemented |
NC0199 # 06 Y:2000 | 06 | 2000 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $5,140 | $0 | Implemented |
DS0169 # 01 Y:2000 | 01 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,062 | $246 | Implemented |
DS0169 # 04 Y:2000 | 04 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,000 | $2,943 | Implemented |
DS0169 # 05 Y:2000 | 05 | 2000 | BURN WASTE OIL FOR HEAT | $5,018 | $1,695 | Implemented |
DS0169 # 07 Y:2000 | 07 | 2000 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $3,694 | $4,083 | Implemented |
DS0169 # 08 Y:2000 | 08 | 2000 | CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE | $5,929 | $12,962 | Implemented |
DS0169 # 09 Y:2000 | 09 | 2000 | INSTALL SHELVES / RACKS TO UTILIZE UNUSED SPACE | $600 | $1,288 | Implemented |
SD0251 # 05 Y:2000 | 05 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,040 | $200 | Implemented |
SD0251 # 06 Y:2000 | 06 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,438 | $1,438 | Implemented |
SD0251 # 08 Y:2000 | 08 | 2000 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $2,240 | $7,900 | Implemented |
OK0594 # 01 Y:2000 | 01 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,935 | $800 | Implemented |
OK0594 # 02 Y:2000 | 02 | 2000 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $8,177 | $13,490 | Implemented |
OK0594 # 03 Y:2000 | 03 | 2000 | INSTALL SKYLIGHTS | $3,419 | $2,000 | Implemented |
OK0594 # 05 Y:2000 | 05 | 2000 | INSTALL OCCUPANCY SENSORS | $3,339 | $860 | Implemented |
ME0281 # 03 Y:2000 | 03 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,461 | $50 | Implemented |
ME0281 # 04 Y:2000 | 04 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,277 | $300 | Implemented |
ME0281 # 05 Y:2000 | 05 | 2000 | UTILIZE A CENTRAL COOLANT SYSTEM FOR CLEANING AND REUSE OF METAL WORKING FLUID | $80,452 | $92,000 | Implemented |
MO0271 # 02 Y:2000 | 02 | 2000 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $7,238 | $9,332 | Implemented |
MO0271 # 03 Y:2000 | 03 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,506 | $175 | Implemented |
CO0450 # 02 Y:1999 | 02 | 1999 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $5,800 | $15,000 | Implemented |
UM0150 # 02 Y:1999 | 02 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $680 | $300 | Implemented |
BD0137 # 03 Y:1999 | 03 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,635 | $225 | Implemented |
BD0137 # 09 Y:1999 | 09 | 1999 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $2,707 | $10,000 | Implemented |
DS0136 # 01 Y:1999 | 01 | 1999 | OPTIMIZE PLANT POWER FACTOR | $1,047 | $1,960 | Implemented |