Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,933
matching recommendationsSIC | 354 | Metalworking Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0212 # 02 Y:2001 | 02 | 2001 | INSTALL OCCUPANCY SENSORS | $261 | $600 | Implemented |
SF0212 # 03 Y:2001 | 03 | 2001 | INSULATE BARE EQUIPMENT | $422 | $1,536 | Not Implemented |
SF0212 # 04 Y:2001 | 04 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $953 | $4,666 | Implemented |
SF0212 # 05 Y:2001 | 05 | 2001 | INTERLOCK HEATING AND AIR CONDITIONING SYSTEMS TO PREVENT SIMULTANEOUS OPERATION | $18,923 | $15,000 | Not Implemented |
WI0387 # 01 Y:2001 | 01 | 2001 | IMPROVE SPACE COMFORT CONDITIONING | $178,421 | $400,000 | n/a |
WI0387 # 02 Y:2001 | 02 | 2001 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $24,138 | $0 | Implemented |
WI0387 # 03 Y:2001 | 03 | 2001 | INSTALL SPECTRAL REFLECTORS / DELAMP | $9,794 | $0 | Implemented |
WI0387 # 04 Y:2001 | 04 | 2001 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $4,726 | $1,994 | Implemented |
WI0387 # 05 Y:2001 | 05 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $712 | $2,050 | Not Implemented |
WI0387 # 06 Y:2001 | 06 | 2001 | INSTALL OCCUPANCY SENSORS | $418 | $300 | Implemented |
WI0387 # 07 Y:2001 | 07 | 2001 | USE EVAPORATION TO CONCENTRATE MATERIAL | $8,770 | $16,000 | Implemented |
WI0387 # 08 Y:2001 | 08 | 2001 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $1,292 | $0 | Not Implemented |
WI0387 # 09 Y:2001 | 09 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $630 | $640 | Implemented |
WI0387 # 10 Y:2001 | 10 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $387 | $90 | Implemented |
NV0170 # 01 Y:2000 | 01 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,657 | $360 | Implemented |
NV0170 # 02 Y:2000 | 02 | 2000 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $1,709 | $95 | Not Implemented |
NV0170 # 03 Y:2000 | 03 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $985 | $100 | Implemented |
NV0170 # 04 Y:2000 | 04 | 2000 | RECOVER AND REUSE WASTE MATERIAL | $8,109 | $14,542 | Implemented |
AS0289 # 01 Y:2000 | 01 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,898 | $18,153 | Implemented |
AS0289 # 02 Y:2000 | 02 | 2000 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $4,081 | $9,000 | Implemented |
AS0289 # 03 Y:2000 | 03 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,126 | $140 | Implemented |
AS0289 # 04 Y:2000 | 04 | 2000 | USE SYNTHETIC LUBRICANT | $1,048 | $694 | Implemented |
AS0289 # 05 Y:2000 | 05 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $481 | $221 | Implemented |
AS0289 # 06 Y:2000 | 06 | 2000 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $301 | $380 | Not Implemented |
AS0289 # 07 Y:2000 | 07 | 2000 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $387 | $60 | Not Implemented |