Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

46

matching recommendations
Reset
SIC 354 Metalworking Machinery
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0845 # 08 Y:2007 08 2007 INSTALL OCCUPANCY SENSORS $3,215 $3,600 Not Implemented
GT0845 # 07 Y:2007 07 2007 RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING $3,956 $4,000 Not Implemented
GT0845 # 06 Y:2007 06 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $24,215 $2,000 Implemented
GT0845 # 05 Y:2007 05 2007 INSTALL TIMERS AND/OR THERMOSTATS $8,290 $4,750 Implemented
GT0845 # 04 Y:2007 04 2007 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $22,129 $26,550 Not Implemented
GT0845 # 03 Y:2007 03 2007 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,196 $0 Not Implemented
GT0845 # 02 Y:2007 02 2007 COMBINE UTILITY METERS $6,697 $0 Not Implemented
GT0845 # 01 Y:2007 01 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $17,571 $31,022 Not Implemented
MA0626 # 02 Y:2007 02 2007 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $6,543 $8,000 Not Implemented
MA0626 # 01 Y:2007 01 2007 RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING $67,278 $157,500 Not Implemented
MA0626 # 03 Y:2007 03 2007 AVOID COOLING OF PROCESS STREAMS OR MATERIALS THAT MUST SUBSEQUENTLY BE HEATED $5,346 $0 Not Implemented
MA0626 # 04 Y:2007 04 2007 AVOID COOLING OF PROCESS STREAMS OR MATERIALS THAT MUST SUBSEQUENTLY BE HEATED $3,465 $2,500 Not Implemented
MA0626 # 05 Y:2007 05 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,602 $5,481 Not Implemented
MA0626 # 06 Y:2007 06 2007 AVOID COOLING OF PROCESS STREAMS OR MATERIALS THAT MUST SUBSEQUENTLY BE HEATED $395 $200 Not Implemented
UM0331 # 05 Y:2007 05 2007 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $606 $0 Implemented
UM0331 # 01 Y:2007 01 2007 RECOVER AND REUSE WASTE MATERIAL $37,752 $38,000 Not Implemented
UM0331 # 02 Y:2007 02 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,146 $12,000 Implemented
UM0331 # 03 Y:2007 03 2007 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER $2,277 $4,600 Not Implemented
UM0331 # 04 Y:2007 04 2007 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $788 $500 Not Implemented
SU0259 # 01 Y:2007 01 2007 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,279 $0 Implemented
SU0259 # 02 Y:2007 02 2007 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $1,332 $0 Not Implemented
SU0259 # 03 Y:2007 03 2007 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $411 $0 Not Implemented
SU0259 # 04 Y:2007 04 2007 AIR CONDITION ONLY SPACE NECESSARY $763 $13 Implemented
SU0259 # 05 Y:2007 05 2007 TURN OFF EQUIPMENT WHEN NOT IN USE $290 $38 Implemented
SU0259 # 06 Y:2007 06 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $221 $50 Implemented