Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
228
matching recommendationsSIC | 3542 | Machine Tools, Metal Forming Types |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0733 # 07 Y:2006 | 07 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,883 | $0 | Not Implemented |
UD0733 # 08 Y:2006 | 08 | 2006 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $2,035 | $0 | Not Implemented |
UD0733 # 09 Y:2006 | 09 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,735 | $0 | Implemented |
UD0733 # 10 Y:2006 | 10 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,267 | $0 | Not Implemented |
UD0733 # 11 Y:2006 | 11 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $512 | $2,200 | Implemented |
CO0564 # 01 Y:2005 | 01 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,670 | $280 | Implemented |
CO0564 # 02 Y:2005 | 02 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $35,290 | $39,650 | Implemented |
CO0564 # 03 Y:2005 | 03 | 2005 | USE SOLAR HEAT TO HEAT MAKE-UP AIR | $11,250 | $72,910 | Not Implemented |
CO0564 # 04 Y:2005 | 04 | 2005 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $7,290 | $25,470 | Not Implemented |
CO0564 # 05 Y:2005 | 05 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,090 | $8,320 | Implemented |
CO0564 # 06 Y:2005 | 06 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $870 | $3,510 | Implemented |
CO0564 # 07 Y:2005 | 07 | 2005 | INSTALL OCCUPANCY SENSORS | $610 | $2,380 | Not Implemented |
CO0564 # 08 Y:2005 | 08 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $430 | $1,400 | Implemented |
UM0191 # 01 Y:2001 | 01 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,160 | $12,637 | Not Implemented |
UM0191 # 02 Y:2001 | 02 | 2001 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $29,810 | $40,000 | Not Implemented |
UM0191 # 03 Y:2001 | 03 | 2001 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $9,050 | $3,150 | Implemented |
UM0191 # 04 Y:2001 | 04 | 2001 | CONDENSE OPERATION INTO ONE BUILDING | $12,695 | $10,000 | Not Implemented |
UM0191 # 05 Y:2001 | 05 | 2001 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $2,708 | $1,250 | Not Implemented |
UD0623 # 01 Y:2001 | 01 | 2001 | USE RADIANT HEATER FOR SPOT HEATING | $32,488 | $128,084 | Not Implemented |
UD0623 # 02 Y:2001 | 02 | 2001 | USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES | $13,412 | $700 | Implemented |
UD0623 # 03 Y:2001 | 03 | 2001 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $12,127 | $196 | Implemented |
UD0623 # 04 Y:2001 | 04 | 2001 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $3,421 | $11,978 | Not Implemented |
UD0623 # 05 Y:2001 | 05 | 2001 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $2,301 | $1,000 | Not Implemented |
UD0623 # 06 Y:2001 | 06 | 2001 | MINIMIZE WATER USAGE | $1,740 | $22 | Implemented |
UD0623 # 07 Y:2001 | 07 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,534 | $1,619 | Implemented |