Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

401

matching recommendations
Reset
SIC 3545 Machine Tool Accessories
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UF0356 # 09 Y:2005 09 2005 RECYCLE FLUORESCENT LAMPS $0 $3,496 Implemented
UF0356 # 01 Y:2005 01 2005 MAKE ICE DURING OFF PEAK HOURS FOR COOLING $0 $150,000 Not Implemented
TA0074 # 01 Y:2004 01 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,000 $14,432 Not Implemented
TA0074 # 02 Y:2004 02 2004 CONTRACT A WOOD PALLET RECYCLING COMPANY $2,340 $72 Not Implemented
TA0074 # 03 Y:2004 03 2004 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $2,340 $2,128 Implemented
TA0074 # 04 Y:2004 04 2004 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $1,590 $43 Implemented
TA0074 # 05 Y:2004 05 2004 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,504 $360 Implemented
TA0074 # 06 Y:2004 06 2004 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $625 $600 Implemented
UM0246 # 01 Y:2004 01 2004 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $34,080 $26,630 Not Implemented
UM0246 # 02 Y:2004 02 2004 INSULATE BARE EQUIPMENT $6,140 $700 Implemented
UM0246 # 03 Y:2004 03 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,885 $100 Implemented
UM0246 # 04 Y:2004 04 2004 RECOVER WASTE HEAT FROM EQUIPMENT $1,380 $500 Implemented
UM0246 # 05 Y:2004 05 2004 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,165 $2,000 Not Implemented
UM0246 # 06 Y:2004 06 2004 ADD AREA LIGHTING SWITCHES $620 $600 Not Implemented
MI0059 # 01 Y:2003 01 2003 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $6,926 $1,000 Not Implemented
MI0059 # 02 Y:2003 02 2003 TURN OFF EQUIPMENT WHEN NOT IN USE $577 $70 Not Implemented
MI0059 # 03 Y:2003 03 2003 TURN OFF EQUIPMENT WHEN NOT IN USE $7,079 $884 Not Implemented
MI0059 # 04 Y:2003 04 2003 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,071 $14 Not Implemented
MI0059 # 05 Y:2003 05 2003 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $381 $1,480 Not Implemented
MI0059 # 06 Y:2003 06 2003 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $315 $286 Not Implemented
MI0059 # 07 Y:2003 07 2003 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $1,556 $260 Not Implemented
MI0059 # 08 Y:2003 08 2003 TURN OFF EQUIPMENT WHEN NOT IN USE $9,297 $4,420 Not Implemented
AS0289 # 01 Y:2000 01 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,898 $18,153 Implemented
AS0289 # 02 Y:2000 02 2000 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $4,081 $9,000 Implemented
AS0289 # 03 Y:2000 03 2000 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,126 $140 Implemented