Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

156

matching recommendations
Reset
SIC 3549 Metalworking Machinery, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0356 # 10 Y:2007 10 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $855 $1,900 Implemented
WV0356 # 09 Y:2007 09 2007 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $942 $1,100 Not Implemented
WV0356 # 08 Y:2007 08 2007 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,061 $1,000 Not Implemented
WV0356 # 07 Y:2007 07 2007 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,349 $1,000 Implemented
WV0356 # 06 Y:2007 06 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,880 $0 Implemented
WV0356 # 05 Y:2007 05 2007 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $2,275 $0 Not Implemented
WV0356 # 04 Y:2007 04 2007 BURN WASTE OIL FOR HEAT $4,096 $3,400 Not Implemented
WV0356 # 03 Y:2007 03 2007 USE HEAT PUMP FOR SPACE CONDITIONING $5,326 $9,600 Implemented
WV0356 # 02 Y:2007 02 2007 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $6,101 $16,300 Not Implemented
WV0356 # 01 Y:2007 01 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,825 $33,400 Not Implemented
OR0420 # 04 Y:2002 04 2002 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $11,195 $5,000 Implemented
OR0420 # 03 Y:2002 03 2002 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $9,883 $0 Implemented
OR0420 # 02 Y:2002 02 2002 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $9,386 $530 Not Implemented
OR0420 # 01 Y:2002 01 2002 CLEAR AND RENT EXISTING SPACE $39,861 $1,920 Not Implemented
OR0420 # 05 Y:2002 05 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,020 $1,200 Implemented
MS0209 # 05 Y:2002 05 2002 BURN WASTE OIL FOR HEAT $1,741 $2,012 Not Implemented
MS0209 # 04 Y:2002 04 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $191 $158 Implemented
MS0209 # 01 Y:2002 01 2002 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $4,200 $75 Implemented
MS0209 # 02 Y:2002 02 2002 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $1,434 $280 Implemented
MS0209 # 06 Y:2002 06 2002 CONTRACT A WOOD PALLET RECYCLING COMPANY $840 $0 Implemented
MS0209 # 03 Y:2002 03 2002 INSTALL TIMERS AND/OR THERMOSTATS $822 $591 Not Implemented
UD0632 # 04 Y:2001 04 2001 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $9,915 $0 Implemented
UD0632 # 03 Y:2001 03 2001 OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES $15,075 $0 Not Implemented
UD0632 # 02 Y:2001 02 2001 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK $33,500 $6,000 Not Implemented
UD0632 # 01 Y:2001 01 2001 OPTIMIZE PLANT POWER FACTOR $94,812 $8,000 Implemented