Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
49
matching recommendationsSIC | 356 | General Industrial Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CM1009 # 02 Y:2022 | 02 | 2022 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $13,200 | $201,300 | Implemented |
CO0687 # 03 Y:2014 | 03 | 2014 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $3,110 | $1,500 | Implemented |
CO0687 # 01 Y:2014 | 01 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,210 | $2,210 | Implemented |
CO0667 # 05 Y:2013 | 05 | 2013 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $2,370 | $4,500 | Implemented |
CO0667 # 03 Y:2013 | 03 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,460 | $11,450 | Implemented |
CO0667 # 02 Y:2013 | 02 | 2013 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,950 | $17,590 | Implemented |
CO0667 # 01 Y:2013 | 01 | 2013 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $21,220 | $50,000 | Implemented |
CO0667 # 04 Y:2013 | 04 | 2013 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $13,790 | $35,250 | Implemented |
CO0667 # 07 Y:2013 | 07 | 2013 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $6,190 | $15,000 | Implemented |
CO0506 # 07 Y:2002 | 07 | 2002 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $4,300 | $5,420 | Implemented |
CO0498 # 05 Y:2001 | 05 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $380 | $210 | Implemented |
CO0498 # 04 Y:2001 | 04 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $410 | $0 | Implemented |
CO0498 # 02 Y:2001 | 02 | 2001 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $2,910 | $5,800 | Implemented |
CO0498 # 06 Y:2001 | 06 | 2001 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $71,500 | $3,200 | Implemented |
CO0156 # 04 Y:1989 | 04 | 1989 | INSTALL TIMERS AND/OR THERMOSTATS | $4,640 | $1,500 | Implemented |
CO0156 # 01 Y:1989 | 01 | 1989 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,970 | $250 | Implemented |
CO0156 # 07 Y:1989 | 07 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $635 | $2,480 | Implemented |
CO0156 # 06 Y:1989 | 06 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $277 | $105 | Implemented |
CO0156 # 05 Y:1989 | 05 | 1989 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,240 | $800 | Implemented |
CO0156 # 03 Y:1989 | 03 | 1989 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,480 | $1,200 | Implemented |
CO0131 # 09 Y:1988 | 09 | 1988 | COVER OPEN TANKS | $1,934 | $1,500 | Implemented |
CO0131 # 03 Y:1988 | 03 | 1988 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $874 | $300 | Implemented |
CO0131 # 04 Y:1988 | 04 | 1988 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $632 | $250 | Implemented |
CO0131 # 06 Y:1988 | 06 | 1988 | INSTALL TIMERS AND/OR THERMOSTATS | $1,035 | $150 | Implemented |
CO0131 # 07 Y:1988 | 07 | 1988 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $16,979 | $4,000 | Implemented |