Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
190
matching recommendationsSIC | 356 | General Industrial Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0816 # 07 Y:2011 | 07 | 2011 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $17,005 | $315,900 | Not Implemented |
OK0816 # 01 Y:2011 | 01 | 2011 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $20,409 | $71,773 | Not Implemented |
OK0816 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $245 | $1,488 | Implemented |
OK0816 # 03 Y:2011 | 03 | 2011 | INSTALL OCCUPANCY SENSORS | $391 | $456 | Implemented |
OK0816 # 04 Y:2011 | 04 | 2011 | DISCONNECT BALLASTS | $481 | $921 | Not Implemented |
OK0816 # 05 Y:2011 | 05 | 2011 | TURN OFF EQUIPMENT WHEN NOT IN USE | $17,462 | $0 | Not Implemented |
OK0816 # 06 Y:2011 | 06 | 2011 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $13,197 | $9,150 | Not Implemented |
OK0812 # 04 Y:2011 | 04 | 2011 | INSTALL OCCUPANCY SENSORS | $6,323 | $26,111 | Implemented |
OK0812 # 05 Y:2011 | 05 | 2011 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $13,390 | $7,255 | Not Implemented |
OK0812 # 06 Y:2011 | 06 | 2011 | SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS | $12,936 | $21,477 | Not Implemented |
OK0812 # 07 Y:2011 | 07 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,301 | $7,605 | Not Implemented |
OK0812 # 08 Y:2011 | 08 | 2011 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $2,925 | $14,300 | Implemented |
OK0812 # 09 Y:2011 | 09 | 2011 | INSTALL TIMERS AND/OR THERMOSTATS | $801 | $353 | Implemented |
OK0812 # 10 Y:2011 | 10 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,148 | $7,130 | Not Implemented |
OK0812 # 02 Y:2011 | 02 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,843 | $750 | Implemented |
OK0812 # 01 Y:2011 | 01 | 2011 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $34,390 | $92,072 | Implemented |
OK0812 # 03 Y:2011 | 03 | 2011 | INSTALL OCCUPANCY SENSORS | $11,401 | $77,770 | Not Implemented |
OK0743 # 07 Y:2007 | 07 | 2007 | INSULATE BARE EQUIPMENT | $5,413 | $723 | Implemented |
OK0743 # 05 Y:2007 | 05 | 2007 | INSTALL OCCUPANCY SENSORS | $21,613 | $2,450 | Implemented |
OK0743 # 01 Y:2007 | 01 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $22,720 | $5,010 | Implemented |
OK0743 # 02 Y:2007 | 02 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,189 | $569 | Implemented |
OK0743 # 04 Y:2007 | 04 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,598 | $3,500 | Implemented |
OK0743 # 03 Y:2007 | 03 | 2007 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $642 | $6,000 | Implemented |
OK0743 # 06 Y:2007 | 06 | 2007 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $24,607 | $0 | Not Implemented |
OK0593 # 06 Y:2000 | 06 | 2000 | USE LOW VOC OR WATER BASED PAINT | $1,315 | $1,350 | Implemented |