Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,257
matching recommendationsSIC | 356 | General Industrial Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0422 # 03 Y:2013 | 03 | 2013 | USE SYNTHETIC LUBRICANT | $4,219 | $4,219 | Not Implemented |
BD0422 # 04 Y:2013 | 04 | 2013 | INSTALL OCCUPANCY SENSORS | $2,518 | $3,225 | Not Implemented |
BD0422 # 05 Y:2013 | 05 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,187 | $25 | Not Implemented |
BD0422 # 06 Y:2013 | 06 | 2013 | USE SYNTHETIC LUBRICANT | $633 | $300 | Not Implemented |
BD0422 # 07 Y:2013 | 07 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $610 | $1,000 | Not Implemented |
BD0422 # 08 Y:2013 | 08 | 2013 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $530 | $500 | Not Implemented |
BD0422 # 09 Y:2013 | 09 | 2013 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $17,739 | $4,600 | Not Implemented |
UA0092 # 01 Y:2013 | 01 | 2013 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $187,982 | $150,000 | Not Implemented |
UA0092 # 02 Y:2013 | 02 | 2013 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $37,964 | $77,760 | Not Implemented |
UA0092 # 03 Y:2013 | 03 | 2013 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $25,845 | $25,121 | Implemented |
UA0092 # 04 Y:2013 | 04 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $62,047 | $15,800 | Not Implemented |
UA0092 # 05 Y:2013 | 05 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $43,460 | $6,200 | Implemented |
UA0092 # 06 Y:2013 | 06 | 2013 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,421 | $135 | Implemented |
CO0667 # 01 Y:2013 | 01 | 2013 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $21,220 | $50,000 | Implemented |
CO0667 # 02 Y:2013 | 02 | 2013 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,950 | $17,590 | Implemented |
CO0667 # 03 Y:2013 | 03 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,460 | $11,450 | Implemented |
CO0667 # 04 Y:2013 | 04 | 2013 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $13,790 | $35,250 | Implemented |
CO0667 # 05 Y:2013 | 05 | 2013 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $2,370 | $4,500 | Implemented |
CO0667 # 06 Y:2013 | 06 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,120 | $15,820 | Not Implemented |
CO0667 # 07 Y:2013 | 07 | 2013 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $6,190 | $15,000 | Implemented |
DL0094 # 01 Y:2012 | 01 | 2012 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $4,550 | $0 | Implemented |
DL0094 # 02 Y:2012 | 02 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,797 | $12,000 | Not Implemented |
DL0094 # 03 Y:2012 | 03 | 2012 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $4,058 | $1,450 | Not Implemented |
DL0094 # 04 Y:2012 | 04 | 2012 | AIR CONDITION ONLY SPACE NECESSARY | $780 | $0 | Implemented |
DL0094 # 05 Y:2012 | 05 | 2012 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $384 | $0 | Not Implemented |