Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
34
matching recommendationsSIC | 3561 | Pumps And Pumping Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0510 # 07 Y:1998 | 07 | 1998 | UTILIZE A CENTRAL COOLANT SYSTEM FOR CLEANING AND REUSE OF METAL WORKING FLUID | $3,900 | $11,720 | Not Implemented |
KU0510 # 01 Y:1998 | 01 | 1998 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $6,740 | $200 | Implemented |
KU0510 # 02 Y:1998 | 02 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,400 | $4,710 | Implemented |
KU0510 # 06 Y:1998 | 06 | 1998 | CONVERT TO AIR ASSISTED / AIRLESS PAINT GUNS | $14,350 | $8,630 | Not Implemented |
KU0510 # 03 Y:1998 | 03 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,670 | $900 | Implemented |
KU0510 # 04 Y:1998 | 04 | 1998 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $350 | $1,000 | Implemented |
KU0510 # 05 Y:1998 | 05 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $310 | $400 | Implemented |
KU0510 # 08 Y:1998 | 08 | 1998 | $1,350 | $2,310 | Implemented | |
WI0329 # 01 Y:1998 | 01 | 1998 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $22,908 | $1,500 | Implemented |
WI0329 # 03 Y:1998 | 03 | 1998 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,092 | $400 | Implemented |
WI0329 # 05 Y:1998 | 05 | 1998 | $3,600 | $9,500 | Not Implemented | |
WI0329 # 02 Y:1998 | 02 | 1998 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $14,336 | $0 | Implemented |
WI0329 # 07 Y:1998 | 07 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $626 | $640 | Implemented |
WI0329 # 04 Y:1998 | 04 | 1998 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $10,231 | $11,400 | Not Implemented |
WI0329 # 06 Y:1998 | 06 | 1998 | INSTALL TIMERS AND/OR THERMOSTATS | $3,445 | $1,600 | Not Implemented |
BD0114 # 04 Y:1998 | 04 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,083 | $2,257 | Implemented |
BD0114 # 09 Y:1998 | 09 | 1998 | $5,289 | $4,395 | Implemented | |
BD0114 # 08 Y:1998 | 08 | 1998 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $1,921 | $1,300 | Not Implemented |
BD0114 # 07 Y:1998 | 07 | 1998 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $2,147 | $250 | Implemented |
BD0114 # 06 Y:1998 | 06 | 1998 | FILTER AND REUSE HYDRAULIC OIL | $4,256 | $1,125 | Not Implemented |
BD0114 # 05 Y:1998 | 05 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $281 | $200 | Not Implemented |
BD0114 # 03 Y:1998 | 03 | 1998 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $2,053 | $5,000 | Not Implemented |
BD0114 # 02 Y:1998 | 02 | 1998 | INSTALL OCCUPANCY SENSORS | $5,471 | $2,025 | Not Implemented |
BD0114 # 01 Y:1998 | 01 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,281 | $15,250 | Implemented |
AR0138 # 05 Y:1998 | 05 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,014 | $998 | Not Implemented |