Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
225
matching recommendationsSIC | 3569 | General Industrial Machinery, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0253 # 04 Y:2004 | 04 | 2004 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $3,806 | $9,583 | Implemented |
UM0253 # 03 Y:2004 | 03 | 2004 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $5,558 | $750 | Implemented |
UM0253 # 02 Y:2004 | 02 | 2004 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $9,810 | $3,150 | Implemented |
UM0253 # 01 Y:2004 | 01 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,527 | $19,692 | Implemented |
UD0690 # 12 Y:2004 | 12 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $430 | $170 | Implemented |
UD0690 # 11 Y:2004 | 11 | 2004 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $352 | $0 | Implemented |
UD0690 # 06 Y:2004 | 06 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,580 | $0 | Implemented |
UD0690 # 04 Y:2004 | 04 | 2004 | REDUCE FLUID FLOW RATES | $4,171 | $2,400 | Implemented |
UD0690 # 03 Y:2004 | 03 | 2004 | INTERLOCK HEATING AND AIR CONDITIONING SYSTEMS TO PREVENT SIMULTANEOUS OPERATION | $4,576 | $7,366 | Implemented |
UD0687 # 10 Y:2004 | 10 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $165 | $15 | Implemented |
UD0687 # 08 Y:2004 | 08 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $365 | $450 | Implemented |
UD0687 # 06 Y:2004 | 06 | 2004 | DISCONNECT BALLASTS | $2,430 | $2,610 | Implemented |
UD0687 # 01 Y:2004 | 01 | 2004 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $4,973 | $1,000 | Implemented |
IA0320 # 01 Y:2003 | 01 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,539 | $449 | Implemented |
IA0320 # 05 Y:2003 | 05 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $520 | $888 | Implemented |
IA0320 # 08 Y:2003 | 08 | 2003 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $10,500 | $0 | Implemented |
AM0422 # 03 Y:2002 | 03 | 2002 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,545 | $30 | Implemented |
AM0422 # 07 Y:2002 | 07 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $345 | $310 | Implemented |
AM0422 # 08 Y:2002 | 08 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $140 | $50 | Implemented |
AM0422 # 05 Y:2002 | 05 | 2002 | PAY UTILITY BILLS ON TIME | $645 | $0 | Implemented |
AM0422 # 02 Y:2002 | 02 | 2002 | CONSIDER USE / PURCHASE OF BULK MATERIALS WHERE POSSIBLE | $13,580 | $5,270 | Implemented |
AM0422 # 04 Y:2002 | 04 | 2002 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $780 | $50 | Implemented |
UD0639 # 03 Y:2002 | 03 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $450 | $1,698 | Implemented |
UD0639 # 02 Y:2002 | 02 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $557 | $2,052 | Implemented |
UD0639 # 04 Y:2002 | 04 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $418 | $0 | Implemented |