Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
430
matching recommendationsSIC | 357 | Computer And Office Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0612 # 11 Y:2007 | 11 | 2007 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $2,799 | $1,800 | Not Implemented |
MA0612 # 10 Y:2007 | 10 | 2007 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $5,532 | $8,000 | Not Implemented |
MA0612 # 09 Y:2007 | 09 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,610 | $18,700 | Not Implemented |
MA0612 # 08 Y:2007 | 08 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $6,240 | $11,700 | Not Implemented |
MA0612 # 07 Y:2007 | 07 | 2007 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $14,963 | $26,370 | Not Implemented |
MA0612 # 06 Y:2007 | 06 | 2007 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $16,924 | $3,200 | Not Implemented |
MA0612 # 05 Y:2007 | 05 | 2007 | REDUCE VENTILATION AIR | $17,480 | $8,040 | Not Implemented |
MA0612 # 04 Y:2007 | 04 | 2007 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $21,000 | $73,760 | Not Implemented |
MA0612 # 03 Y:2007 | 03 | 2007 | MODERATE COOLING TOWER OUTLET TEMPERATURE | $23,433 | $12,750 | Not Implemented |
MA0612 # 02 Y:2007 | 02 | 2007 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $57,921 | $108,000 | Not Implemented |
MA0612 # 01 Y:2007 | 01 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $96,635 | $175,500 | Not Implemented |
LM0122 # 01 Y:2007 | 01 | 2007 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $42,830 | $89,250 | Not Implemented |
LM0122 # 02 Y:2007 | 02 | 2007 | ISOLATE HOT OR COLD EQUIPMENT | $814 | $2,000 | Not Implemented |
LM0122 # 03 Y:2007 | 03 | 2007 | INSTALL OCCUPANCY SENSORS | $1,465 | $3,975 | Not Implemented |
LM0122 # 04 Y:2007 | 04 | 2007 | $19,128 | $5,500 | Implemented | |
LM0122 # 05 Y:2007 | 05 | 2007 | $9,311 | $4,850 | Implemented | |
OR0500 # 05 Y:2006 | 05 | 2006 | OPTIMIZE PLANT POWER FACTOR | $16,600 | $10,100 | Not Implemented |
OR0500 # 04 Y:2006 | 04 | 2006 | MINIMIZE WATER USAGE | $51,600 | $105,000 | Not Implemented |
OR0500 # 03 Y:2006 | 03 | 2006 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $39,400 | $42,000 | Implemented |
OR0500 # 02 Y:2006 | 02 | 2006 | INSTALL COMMON HEADER ON COMPRESSORS | $36,300 | $31,500 | Implemented |
OR0500 # 01 Y:2006 | 01 | 2006 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $23,000 | $31,500 | Implemented |
OR0500 # 06 Y:2006 | 06 | 2006 | INSTALL OCCUPANCY SENSORS | $15,000 | $4,800 | Not Implemented |
OR0500 # 07 Y:2006 | 07 | 2006 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,400 | $1,200 | Not Implemented |
AS0420 # 04 Y:2006 | 04 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,765 | $1,000 | Not Implemented |
AS0420 # 03 Y:2006 | 03 | 2006 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $2,254 | $3,300 | Not Implemented |