Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,672

matching recommendations
Reset
SIC 358 Refrigeration And Service Machinery
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0183 # 06 Y:2000 06 2000 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $4,983 $10,750 Not Implemented
NC0183 # 07 Y:2000 07 2000 USE DISTILLATION, EVAPORATION TO REMOVE CONTAMINANTS $13,598 $12,000 Not Implemented
NC0183 # 08 Y:2000 08 2000 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $6,838 $3,700 Implemented
NC0183 # 09 Y:2000 09 2000 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $500 $500 Not Implemented
NC0183 # 10 Y:2000 10 2000 SCHEDULE DELIVERIES ACCORDING TO DEMAND $20,448 $5,000 Implemented
MS0152 # 01 Y:2000 01 2000 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $331 $136 Not Implemented
MS0152 # 02 Y:2000 02 2000 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $8,518 $457 Implemented
MS0152 # 03 Y:2000 03 2000 RECOVER WASTE HEAT FROM EQUIPMENT $3,651 $3,747 Not Implemented
MS0152 # 04 Y:2000 04 2000 INSTALL TIMERS AND/OR THERMOSTATS $3,911 $2,652 Implemented
MS0152 # 05 Y:2000 05 2000 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $1,407 $4,000 Not Implemented
MS0152 # 06 Y:2000 06 2000 BURN WASTE OIL FOR HEAT $432 $1,974 Not Implemented
MS0152 # 07 Y:2000 07 2000 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION $8,948 $4,500 Not Implemented
WI0358 # 01 Y:1999 01 1999 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $97,790 $44,000 Implemented
WI0358 # 02 Y:1999 02 1999 SHIFT FROM DAYTIME TO NIGHTTIME OPERATION $92,705 $0 Not Implemented
WI0358 # 03 Y:1999 03 1999 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT $54,425 $102,000 Not Implemented
WI0358 # 04 Y:1999 04 1999 DISTILL CONTAMINATED SOLVENTS FOR REUSE $7,803 $13,900 Not Implemented
WI0358 # 05 Y:1999 05 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $6,466 $200 Not Implemented
WI0358 # 06 Y:1999 06 1999 INSULATE BARE EQUIPMENT $1,096 $3,850 Not Implemented
WI0358 # 07 Y:1999 07 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $331 $107 Implemented
CO0443 # 01 Y:1999 01 1999 TURN OFF EQUIPMENT WHEN NOT IN USE $16,960 $0 Implemented
CO0443 # 02 Y:1999 02 1999 REDUCE VENTILATION AIR $11,050 $12,600 Not Implemented
CO0443 # 03 Y:1999 03 1999 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $7,900 $250 Implemented
CO0443 # 04 Y:1999 04 1999 USE DEMAND CONTROLLER OR LOAD SHEDDER $5,760 $2,000 Implemented
CO0443 # 05 Y:1999 05 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,660 $530 Implemented
CO0443 # 06 Y:1999 06 1999 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $2,210 $1,000 Implemented