Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

77

matching recommendations
Reset
SIC 359 Industrial Machinery, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UM0291 # 06 Y:2005 06 2005 USE DOUBLE OR TRIPLE GLAZED WINDOWS TO MAINTAIN HIGHER RELATIVE HUMIDITY AND TO REDUCE HEAT LOSSES $2,309 $39,000 Not Implemented
UM0291 # 07 Y:2005 07 2005 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $1,325 $1,265 Implemented
UM0291 # 08 Y:2005 08 2005 INSTALL OCCUPANCY SENSORS $396 $150 Not Implemented
UM0140 # 07 Y:1999 07 1999 MODIFY STARTUP/SHUTDOWN TIMES $36,686 $0 Not Implemented
UM0140 # 06 Y:1999 06 1999 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $2,613 $0 Not Implemented
UM0140 # 04 Y:1999 04 1999 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $2,688 $3,600 Not Implemented
UM0140 # 02 Y:1999 02 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,110 $600 Not Implemented
UM0140 # 05 Y:1999 05 1999 USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS $225,811 $90,000 Not Implemented
UM0140 # 01 Y:1999 01 1999 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $18,168 $780 Not Implemented
UM0140 # 03 Y:1999 03 1999 RESCHEDULE AND REARRANGE MULTIPLE-SOURCE HEATING SYSTEMS $27,426 $13,000 Not Implemented
UM0103 # 04 Y:1998 04 1998 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $1,733 $0 Not Implemented
UM0103 # 03 Y:1998 03 1998 INSTALL OCCUPANCY SENSORS $490 $500 Not Implemented
UM0103 # 06 Y:1998 06 1998 USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS $1,435 $4,535 Not Implemented
UM0103 # 07 Y:1998 07 1998 TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY $1,962 $200 Implemented
UM0103 # 02 Y:1998 02 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,518 $3,418 Not Implemented
UM0103 # 05 Y:1998 05 1998 SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE $15,000 $1,500 Not Implemented
UM0103 # 01 Y:1998 01 1998 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $173 $157 Not Implemented
ND0289 # 04 Y:1997 04 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,301 $500 Not Implemented
ND0289 # 06 Y:1997 06 1997 INSTALL OCCUPANCY SENSORS $701 $600 Not Implemented
ND0289 # 07 Y:1997 07 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $545 $53 Implemented
ND0289 # 08 Y:1997 08 1997 CONTRACT A WOOD PALLET RECYCLING COMPANY $312 $0 Not Implemented
ND0289 # 09 Y:1997 09 1997 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $185 $516 Not Implemented
ND0289 # 10 Y:1997 10 1997 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS $180 $200 Not Implemented
ND0289 # 11 Y:1997 11 1997 SCHEDULE DELIVERIES ACCORDING TO DEMAND $135 $0 Not Implemented
ND0289 # 12 Y:1997 12 1997 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $103 $57 Implemented