Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

86

matching recommendations
Reset
SIC 359 Industrial Machinery, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LE0403 # 11 Y:2015 11 2015 RECOVER WASTE HEAT FROM EQUIPMENT $489 $1,750 Not Implemented
LE0304 # 09 Y:2010 09 2010 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $1,073 $5,740 Not Implemented
LE0304 # 12 Y:2010 12 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,240 $11,654 Implemented
LE0304 # 10 Y:2010 10 2010 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $803 $2,400 Not Implemented
LE0304 # 08 Y:2010 08 2010 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $1,370 $0 Not Implemented
LE0304 # 07 Y:2010 07 2010 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $7,396 $273 Implemented
LE0304 # 06 Y:2010 06 2010 RECOVER WASTE HEAT FROM EQUIPMENT $8,592 $15,000 Not Implemented
LE0304 # 05 Y:2010 05 2010 INSTALL TIMERS AND/OR THERMOSTATS $12,804 $30 Implemented
LE0304 # 04 Y:2010 04 2010 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $15,355 $100,000 Not Implemented
LE0304 # 03 Y:2010 03 2010 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $16,822 $18,000 Not Implemented
LE0304 # 02 Y:2010 02 2010 USE RADIANT HEATER FOR SPOT HEATING $55,099 $39,415 Not Implemented
LE0304 # 01 Y:2010 01 2010 USE RADIANT HEATER FOR SPOT HEATING $300,000 $40,932 Not Implemented
LE0304 # 11 Y:2010 11 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,692 $14,758 Implemented
LE0280 # 06 Y:2008 06 2008 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $144 $560 Not Implemented
LE0280 # 01 Y:2008 01 2008 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $23,492 $40,000 Not Implemented
LE0280 # 02 Y:2008 02 2008 TURN OFF EQUIPMENT WHEN NOT IN USE $8,407 $3,000 Implemented
LE0280 # 03 Y:2008 03 2008 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,749 $980 Implemented
LE0280 # 04 Y:2008 04 2008 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $3,154 $12,000 Not Implemented
LE0280 # 05 Y:2008 05 2008 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,767 $1,000 Implemented
LE0280 # 07 Y:2008 07 2008 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $23,579 $65,839 Implemented
WV0364 # 02 Y:2007 02 2007 INSULATE BARE EQUIPMENT $29,507 $12,903 Implemented
WV0364 # 04 Y:2007 04 2007 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $25,424 $32,700 Implemented
WV0364 # 13 Y:2007 13 2007 UTILIZE A LESS EXPENSIVE COOLING METHOD $1,174 $2,445 Not Implemented
WV0364 # 01 Y:2007 01 2007 USE DEMAND CONTROLLER OR LOAD SHEDDER $37,506 $7,700 Not Implemented
WV0364 # 03 Y:2007 03 2007 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $28,283 $0 Implemented