Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,249

matching recommendations
Reset
SIC 359 Industrial Machinery, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0211 # 07 Y:2001 07 2001 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $3,353 $20 Not Implemented
WV0211 # 08 Y:2001 08 2001 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM $1,545 $400 Implemented
WV0211 # 09 Y:2001 09 2001 INSTALL OCCUPANCY SENSORS $1,150 $500 Implemented
WV0211 # 10 Y:2001 10 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $848 $120 Implemented
WV0211 # 11 Y:2001 11 2001 USE OPTIMUM THICKNESS INSULATION $538 $510 Implemented
WV0211 # 12 Y:2001 12 2001 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $379 $2,075 Not Implemented
WV0211 # 13 Y:2001 13 2001 RECOVER WASTE HEAT FROM EQUIPMENT $474 $780 Not Implemented
WV0211 # 14 Y:2001 14 2001 INSULATE BARE EQUIPMENT $261 $128 Implemented
WV0211 # 15 Y:2001 15 2001 INSULATE BARE EQUIPMENT $135 $69 Implemented
WV0211 # 16 Y:2001 16 2001 REUSE SCRAP GLASS AS FEED STOCK $48 $0 Not Implemented
WV0211 # 17 Y:2001 17 2001 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $1,662 $1,500 Not Implemented
WV0211 # 18 Y:2001 18 2001 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $20,000 $1,300 Not Implemented
UD0612 # 01 Y:2001 01 2001 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,331 $200 Implemented
UD0612 # 02 Y:2001 02 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,820 $4,275 Not Implemented
UD0612 # 03 Y:2001 03 2001 INSTALL TIMERS AND/OR THERMOSTATS $782 $800 Implemented
UD0612 # 04 Y:2001 04 2001 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $765 $3,000 Not Implemented
UD0612 # 05 Y:2001 05 2001 USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES $533 $1,200 Implemented
UD0612 # 06 Y:2001 06 2001 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $528 $600 Not Implemented
LL0102 # 01 Y:2001 01 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $672 $2,135 Not Implemented
LL0102 # 02 Y:2001 02 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $655 $3,697 Implemented
LL0102 # 03 Y:2001 03 2001 OPTIMIZE PLANT POWER FACTOR $1,262 $1,200 Implemented
LL0102 # 04 Y:2001 04 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,140 $2,890 Implemented
LL0102 # 05 Y:2001 05 2001 REDUCE SCRAP PRODUCTION $1,349 $0 Implemented
BD0177 # 01 Y:2001 01 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,288 $500 Implemented
BD0177 # 02 Y:2001 02 2001 INSTALL OCCUPANCY SENSORS $3,171 $1,425 Not Implemented