IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,164

matching recommendations
Reset
SIC 359 Industrial Machinery, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TN0636 # 03 Y:1998 03 1998 INSULATE BARE EQUIPMENT $670 $220 Implemented
TN0636 # 04 Y:1998 04 1998 RECOVER WASTE HEAT FROM EQUIPMENT $490 $980 Not Implemented
TN0636 # 05 Y:1998 05 1998 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $175 $0 Implemented
TN0636 # 06 Y:1998 06 1998 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $150 $600 Implemented
OD0104 # 01 Y:1998 01 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,047 $8,241 Not Implemented
OD0104 # 02 Y:1998 02 1998 RECOVER WASTE HEAT FROM EQUIPMENT $809 $200 Not Implemented
OD0104 # 03 Y:1998 03 1998 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $453 $98 Not Implemented
OD0104 # 04 Y:1998 04 1998 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $5,445 $11,000 Not Implemented
OD0104 # 05 Y:1998 05 1998 USE SYNTHETIC LUBRICANT $270 $59 Not Implemented
OD0104 # 06 Y:1998 06 1998 $2,145 $500 Not Implemented
UD0536 # 03 Y:1998 03 1998 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $3,884 $-6,000 Not Implemented
UD0536 # 04 Y:1998 04 1998 USE OTHER WASTE CONCENTRATION METHODS $3,341 $15,000 Not Implemented
UD0536 # 05 Y:1998 05 1998 CONTRACT A WOOD PALLET RECYCLING COMPANY $2,000 $0 Implemented
UD0536 # 01 Y:1998 01 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,739 $17,011 Implemented
UD0536 # 02 Y:1998 02 1998 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $6,150 $12,500 Not Implemented
UM0103 # 01 Y:1998 01 1998 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $173 $157 Not Implemented
UM0103 # 02 Y:1998 02 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,518 $3,418 Not Implemented
UM0103 # 03 Y:1998 03 1998 INSTALL OCCUPANCY SENSORS $490 $500 Not Implemented
UM0103 # 04 Y:1998 04 1998 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $1,733 $0 Not Implemented
UM0103 # 05 Y:1998 05 1998 SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE $15,000 $1,500 Not Implemented
UM0103 # 06 Y:1998 06 1998 USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS $1,435 $4,535 Not Implemented
UM0103 # 07 Y:1998 07 1998 $1,962 $200 Implemented
ND0289 # 01 Y:1997 01 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,054 $2,780 Implemented
ND0289 # 02 Y:1997 02 1997 USE ALTERNATIVES FOR ACIDS / ALKALINE (WATER, STEAM, ABRASIVE) $3,386 $50 Not Implemented
ND0289 # 03 Y:1997 03 1997 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $1,506 $582 Not Implemented