Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,791
matching recommendationsSIC | 36 | Electronic & Other Electric Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0246 # 01 Y:1988 | 01 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,686 | $1,650 | Implemented |
KU0246 # 02 Y:1988 | 02 | 1988 | INSTALL TIMERS AND/OR THERMOSTATS | $2,577 | $800 | Implemented |
KU0246 # 03 Y:1988 | 03 | 1988 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,601 | $300 | Implemented |
KU0246 # 04 Y:1988 | 04 | 1988 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $1,886 | $3,600 | Implemented |
KU0246 # 05 Y:1988 | 05 | 1988 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,278 | $0 | Implemented |
KU0246 # 07 Y:1988 | 07 | 1988 | REPLACE BROKEN WINDOWS AND/OR WINDOW SASH | $239 | $200 | Implemented |
KU0246 # 08 Y:1988 | 08 | 1988 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $116 | $0 | Implemented |
RU0021 # 01 Y:1988 | 01 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,128 | $370 | Implemented |
RU0021 # 02 Y:1988 | 02 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $302 | $0 | Implemented |
RU0021 # 04 Y:1988 | 04 | 1988 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $956 | $800 | Implemented |
RU0021 # 06 Y:1988 | 06 | 1988 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $4,095 | $400 | Implemented |
OK0248 # 01 Y:1988 | 01 | 1988 | INSTALL TIMERS AND/OR THERMOSTATS | $2,293 | $2,800 | Implemented |
OK0248 # 02 Y:1988 | 02 | 1988 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,639 | $0 | Implemented |
OK0248 # 03 Y:1988 | 03 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $626 | $1,500 | Implemented |
OK0248 # 04 Y:1988 | 04 | 1988 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $9,415 | $0 | Implemented |
TN0329 # 04 Y:1988 | 04 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,619 | $0 | Implemented |
TN0329 # 05 Y:1988 | 05 | 1988 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,783 | $3,300 | Implemented |
TN0329 # 06 Y:1988 | 06 | 1988 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,824 | $1,180 | Implemented |
TN0329 # 07 Y:1988 | 07 | 1988 | IMPROVE LUBRICATION PRACTICES | $1,824 | $0 | Implemented |
TN0329 # 09 Y:1988 | 09 | 1988 | INSULATE BARE EQUIPMENT | $1,106 | $146 | Implemented |
TN0329 # 10 Y:1988 | 10 | 1988 | COVER OPEN TANKS | $252 | $0 | Implemented |
TN0329 # 12 Y:1988 | 12 | 1988 | ISOLATE STEAM LINES TO AVOID HEATING AIR CONDITIONED AREAS | $179 | $600 | Implemented |
UD0251 # 01 Y:1988 | 01 | 1988 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $9,500 | $15,000 | Implemented |
UD0251 # 02 Y:1988 | 02 | 1988 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $7,275 | $0 | Implemented |
UD0251 # 05 Y:1988 | 05 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $882 | $300 | Implemented |