Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
8,559
matching recommendationsSIC | 36 | Electronic & Other Electric Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TT0050 # 03 Y:2010 | 03 | 2010 | USE OPTIMUM THICKNESS INSULATION | $6,800 | $1,000 | Not Implemented |
TT0050 # 04 Y:2010 | 04 | 2010 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $4,900 | $500 | Implemented |
TT0050 # 05 Y:2010 | 05 | 2010 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $2,200 | $0 | Implemented |
TT0050 # 06 Y:2010 | 06 | 2010 | INSTALL OCCUPANCY SENSORS | $500 | $400 | Not Implemented |
OK0788 # 01 Y:2010 | 01 | 2010 | INSTALL / REPAIR INSULATION ON STEAM LINES | $285 | $451 | Implemented |
OK0788 # 02 Y:2010 | 02 | 2010 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $29,667 | $2,587 | Not Implemented |
OK0788 # 03 Y:2010 | 03 | 2010 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $1,568 | $1,078 | Not Implemented |
OK0788 # 04 Y:2010 | 04 | 2010 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $3,625 | $1,176 | Implemented |
OK0788 # 05 Y:2010 | 05 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,103 | $5,543 | Not Implemented |
OK0788 # 06 Y:2010 | 06 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,350 | $8,818 | Implemented |
OK0788 # 07 Y:2010 | 07 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $35,265 | $98,109 | Implemented |
OK0788 # 08 Y:2010 | 08 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $441 | $1,170 | Not Implemented |
OK0788 # 09 Y:2010 | 09 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,877 | $0 | Not Implemented |
OK0788 # 10 Y:2010 | 10 | 2010 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $15,837 | $12,000 | Implemented |
OK0788 # 11 Y:2010 | 11 | 2010 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $6,106 | $101,906 | Not Implemented |
OK0788 # 12 Y:2010 | 12 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $22,393 | $7,656 | Not Implemented |
MS0352 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $92,249 | $34,416 | Not Implemented |
MS0352 # 02 Y:2010 | 02 | 2010 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $6,626 | $5,300 | Not Implemented |
MS0352 # 03 Y:2010 | 03 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,061 | $389 | Not Implemented |
MS0352 # 04 Y:2010 | 04 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,750 | $9,711 | Not Implemented |
MS0352 # 05 Y:2010 | 05 | 2010 | INSTALL OCCUPANCY SENSORS | $284 | $393 | Not Implemented |
NC0400 # 01 Y:2010 | 01 | 2010 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $25,103 | $60,000 | Not Implemented |
NC0400 # 02 Y:2010 | 02 | 2010 | CONVERT LIQUID HEATERS FROM UNDERFIRING TO IMMERSION OR SUBMERSION HEATING | $9,007 | $37,000 | Implemented |
NC0400 # 03 Y:2010 | 03 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,571 | $11,072 | Not Implemented |
NC0400 # 04 Y:2010 | 04 | 2010 | DEVELOP A REPAIR/REPLACE POLICY | $1,761 | $4,346 | Implemented |