Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
8,559
matching recommendationsSIC | 36 | Electronic & Other Electric Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0400 # 05 Y:2010 | 05 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $75 | $200 | Implemented |
AM0571 # 01 Y:2010 | 01 | 2010 | OPTIMIZE PLANT POWER FACTOR | $34,630 | $98,400 | Not Implemented |
AM0571 # 02 Y:2010 | 02 | 2010 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $33,740 | $2,160 | Not Implemented |
AM0571 # 03 Y:2010 | 03 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $24,200 | $300 | Implemented |
AM0571 # 04 Y:2010 | 04 | 2010 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $10,010 | $31,300 | Implemented |
AM0571 # 05 Y:2010 | 05 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,400 | $1,500 | Implemented |
AM0571 # 06 Y:2010 | 06 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,700 | $1,900 | Implemented |
AM0571 # 07 Y:2010 | 07 | 2010 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $5,605 | $0 | Implemented |
AM0571 # 08 Y:2010 | 08 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,000 | $1,500 | Implemented |
UF0430 # 01 Y:2010 | 01 | 2010 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $28,959 | $5,655 | Implemented |
UF0430 # 02 Y:2010 | 02 | 2010 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,044 | $0 | Implemented |
UF0430 # 03 Y:2010 | 03 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,531 | $0 | Not Implemented |
UF0430 # 04 Y:2010 | 04 | 2010 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,547 | $0 | Implemented |
UF0430 # 05 Y:2010 | 05 | 2010 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,211 | $0 | Not Implemented |
UF0430 # 06 Y:2010 | 06 | 2010 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $86,549 | $4,000 | Not Implemented |
UF0430 # 07 Y:2010 | 07 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,016 | $404 | Implemented |
UF0430 # 08 Y:2010 | 08 | 2010 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $6,842 | $0 | Implemented |
UF0428 # 01 Y:2009 | 01 | 2009 | MINIMIZE USE OF RAGS THROUGH WORKER TRAINING | $1,734 | $0 | Implemented |
UF0428 # 02 Y:2009 | 02 | 2009 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,365 | $0 | Implemented |
UF0428 # 03 Y:2009 | 03 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,980 | $5,895 | Implemented |
UF0428 # 04 Y:2009 | 04 | 2009 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $6,371 | $2,260 | Not Implemented |
UF0428 # 05 Y:2009 | 05 | 2009 | INSTALL OCCUPANCY SENSORS | $872 | $1,971 | Implemented |
UF0428 # 06 Y:2009 | 06 | 2009 | INSTALL COMMON HEADER ON COMPRESSORS | $674 | $0 | Not Implemented |
UF0428 # 07 Y:2009 | 07 | 2009 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $4,285 | $0 | Implemented |
UF0428 # 08 Y:2009 | 08 | 2009 | OPTIMIZE PLANT POWER FACTOR | $44,818 | $3,326 | Not Implemented |