Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
285
matching recommendationsSIC | 36 | Electronic & Other Electric Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0152 # 09 Y:1998 | 09 | 1998 | EXPAND OPERATIONS INTO UNUSED SPACE | $31,250 | $12,850 | Not Implemented |
NC0120 # 01 Y:1997 | 01 | 1997 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $21,317 | $8,000 | Implemented |
NC0120 # 02 Y:1997 | 02 | 1997 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $3,966 | $2,000 | Not Implemented |
NC0120 # 03 Y:1997 | 03 | 1997 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,624 | $320 | Implemented |
NC0120 # 04 Y:1997 | 04 | 1997 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,893 | $1,300 | Not Implemented |
NC0120 # 05 Y:1997 | 05 | 1997 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,005 | $0 | Implemented |
NC0120 # 06 Y:1997 | 06 | 1997 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $2,834 | $2,500 | Not Implemented |
NC0120 # 07 Y:1997 | 07 | 1997 | USE COUNTER CURRENT RINSING TO REDUCE WASTE WATER | $965 | $610 | Not Implemented |
NC0120 # 08 Y:1997 | 08 | 1997 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $1,063 | $5,200 | Implemented |
NC0099 # 01 Y:1996 | 01 | 1996 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $1,822 | $7,500 | n/a |
NC0099 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,237 | $27,552 | n/a |
NC0099 # 03 Y:1996 | 03 | 1996 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $201 | $40 | n/a |
NC0099 # 04 Y:1996 | 04 | 1996 | USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE | $289 | $10 | n/a |
NC0099 # 05 Y:1996 | 05 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,927 | $200 | n/a |
NC0099 # 06 Y:1996 | 06 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,592 | $390 | n/a |
NC0099 # 07 Y:1996 | 07 | 1996 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $5,397 | $1,600 | n/a |
NC0099 # 08 Y:1996 | 08 | 1996 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $31,584 | $66,000 | n/a |
OD0042 # 01 Y:1995 | 01 | 1995 | METER WASTE WATER | $32,200 | $717 | Implemented |
OD0042 # 02 Y:1995 | 02 | 1995 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $29,544 | $5,168 | Implemented |
OD0042 # 03 Y:1995 | 03 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $37,136 | $66,487 | Implemented |
OD0042 # 04 Y:1995 | 04 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,061 | $3,657 | Implemented |
OD0042 # 05 Y:1995 | 05 | 1995 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $7,916 | $2,449 | Not Implemented |
OD0042 # 06 Y:1995 | 06 | 1995 | INSTALL TIMERS AND/OR THERMOSTATS | $2,074 | $1,170 | Not Implemented |
OD0042 # 07 Y:1995 | 07 | 1995 | DO NOT USE COMPRESSED AIR FOR PERSONAL COOLING | $462 | $20 | Not Implemented |
NC0050 # 01 Y:1995 | 01 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,208 | $4,662 | Implemented |