Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
580
matching recommendationsSIC | 3621 | Motors And Generators |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0588 # 04 Y:2000 | 04 | 2000 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $525 | $60 | Not Implemented |
OK0588 # 05 Y:2000 | 05 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,662 | $6,960 | Not Implemented |
OK0588 # 06 Y:2000 | 06 | 2000 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $36,400 | $65,450 | Not Implemented |
OK0588 # 07 Y:2000 | 07 | 2000 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $18,000 | $0 | Not Implemented |
OK0588 # 08 Y:2000 | 08 | 2000 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $24,375 | $65,000 | Not Implemented |
TN0672 # 01 Y:2000 | 01 | 2000 | MOVE PRODUCT USING MECHANICAL MEANS | $65,150 | $167,200 | Not Implemented |
TN0672 # 02 Y:2000 | 02 | 2000 | MINIMIZE USE OF RAGS THROUGH WORKER TRAINING | $30,000 | $0 | Not Implemented |
TN0672 # 03 Y:2000 | 03 | 2000 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $18,266 | $27,000 | Not Implemented |
TN0672 # 04 Y:2000 | 04 | 2000 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $14,770 | $17,800 | Not Implemented |
TN0672 # 05 Y:2000 | 05 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $13,010 | $1,650 | Not Implemented |
TN0672 # 06 Y:2000 | 06 | 2000 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $8,990 | $19,000 | Not Implemented |
TN0672 # 07 Y:2000 | 07 | 2000 | REDUCE OR ELIMINATE WASTE | $8,100 | $3,650 | Not Implemented |
TN0672 # 08 Y:2000 | 08 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $7,385 | $13,750 | Not Implemented |
TN0672 # 09 Y:2000 | 09 | 2000 | COVER OPEN TANKS | $7,260 | $1,500 | Not Implemented |
TN0672 # 10 Y:2000 | 10 | 2000 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $6,380 | $13,800 | Not Implemented |
TN0672 # 11 Y:2000 | 11 | 2000 | USE SYNTHETIC LUBRICANT | $3,630 | $0 | Not Implemented |
TN0672 # 12 Y:2000 | 12 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,770 | $1,440 | Not Implemented |
TN0672 # 13 Y:2000 | 13 | 2000 | CHANGE PRODUCT DESIGN TO REDUCE ENERGY REQUIREMENTS | $1,920 | $5,000 | Not Implemented |
WI0354 # 01 Y:1999 | 01 | 1999 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $7,740 | $21,000 | Not Implemented |
WI0354 # 02 Y:1999 | 02 | 1999 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $5,469 | $500 | Implemented |
WI0354 # 03 Y:1999 | 03 | 1999 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $5,465 | $0 | Implemented |
WI0354 # 04 Y:1999 | 04 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,567 | $18,988 | Implemented |
WI0354 # 05 Y:1999 | 05 | 1999 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $2,618 | $500 | Not Implemented |
WI0354 # 06 Y:1999 | 06 | 1999 | INSTALL TIMERS AND/OR THERMOSTATS | $2,328 | $400 | Implemented |
WI0354 # 07 Y:1999 | 07 | 1999 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $1,418 | $4,850 | Not Implemented |