Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
620
matching recommendationsSIC | 364 | Electric Lighting And Wiring Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
HO0109 # 01 Y:1995 | 01 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,587 | $5,326 | Implemented |
HO0109 # 03 Y:1995 | 03 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,804 | $350 | Implemented |
HO0109 # 04 Y:1995 | 04 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $683 | $680 | Implemented |
HO0109 # 05 Y:1995 | 05 | 1995 | KEEP BOILER TUBES CLEAN | $723 | $2,000 | Implemented |
HO0109 # 06 Y:1995 | 06 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $686 | $315 | Implemented |
BD0027 # 01 Y:1995 | 01 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,804 | $450 | Implemented |
UD0451 # 01 Y:1995 | 01 | 1995 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $11,837 | $2,000 | Implemented |
UD0451 # 02 Y:1995 | 02 | 1995 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $17,100 | $0 | Implemented |
MA0319 # 02 Y:1994 | 02 | 1994 | OPTIMIZE PLANT POWER FACTOR | $5,357 | $12,000 | Implemented |
SF0040 # 01 Y:1994 | 01 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $973 | $1,785 | Implemented |
SF0040 # 02 Y:1994 | 02 | 1994 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,250 | $0 | Implemented |
SF0040 # 03 Y:1994 | 03 | 1994 | OPTIMIZE PLANT POWER FACTOR | $811 | $1,150 | Implemented |
SF0040 # 04 Y:1994 | 04 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $409 | $1,013 | Implemented |
SF0040 # 05 Y:1994 | 05 | 1994 | USE SYNTHETIC LUBRICANT | $444 | $0 | Implemented |
SF0040 # 06 Y:1994 | 06 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,261 | $600 | Implemented |
WI0214 # 03 Y:1994 | 03 | 1994 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $9,933 | $600 | Implemented |
WI0214 # 04 Y:1994 | 04 | 1994 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $3,450 | $350 | Implemented |
WI0214 # 05 Y:1994 | 05 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,054 | $2,036 | Implemented |
WI0214 # 07 Y:1994 | 07 | 1994 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,682 | $500 | Implemented |
WI0214 # 09 Y:1994 | 09 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,642 | $640 | Implemented |
AR0025 # 01 Y:1994 | 01 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,649 | $300 | Implemented |
AR0025 # 02 Y:1994 | 02 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,122 | $1,456 | Implemented |
AR0025 # 03 Y:1994 | 03 | 1994 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $4,184 | $725 | Implemented |
AR0025 # 05 Y:1994 | 05 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $7,343 | $9,530 | Implemented |
AR0025 # 06 Y:1994 | 06 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,863 | $600 | Implemented |