IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

61

matching recommendations
Reset
SIC 367 Electronic Components And Accessories
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0613 # 02 Y:2007 02 2007 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $15,346 $54,617 Implemented
MA0613 # 01 Y:2007 01 2007 REDUCE VENTILATION AIR $22,488 $15,475 Implemented
HO0214 # 02 Y:1999 02 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $723 $1,500 Not Implemented
HO0214 # 01 Y:1999 01 1999 INSTALL OCCUPANCY SENSORS $1,313 $1,600 Not Implemented
HO0214 # 03 Y:1999 03 1999 INSULATE BARE EQUIPMENT $3,454 $3,900 Not Implemented
HO0214 # 04 Y:1999 04 1999 USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT $9,653 $0 Not Implemented
HO0214 # 05 Y:1999 05 1999 INSULATE BARE EQUIPMENT $1,927 $2,160 Not Implemented
HO0214 # 06 Y:1999 06 1999 COVER OPEN TANKS $3,955 $4,450 Not Implemented
HO0214 # 07 Y:1999 07 1999 CHANGE OPERATING CONDITIONS $7,654 $20,000 Not Implemented
HO0214 # 08 Y:1999 08 1999 IMPROVE SPACE COMFORT CONDITIONING $1,980 $1,030 Not Implemented
HO0214 # 09 Y:1999 09 1999 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $1,800 $120 Implemented
HO0214 # 10 Y:1999 10 1999 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $25,000 $800 Not Implemented
MA0394 # 02 Y:1997 02 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $89,097 $320,340 Implemented
MA0394 # 06 Y:1997 06 1997 USE A DIFFERENT OR RECYCLED RAW MATERIAL $1,120 $0 Not Implemented
MA0394 # 05 Y:1997 05 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,330 $271 Implemented
MA0394 # 04 Y:1997 04 1997 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $3,246 $4,225 Not Implemented
MA0394 # 03 Y:1997 03 1997 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $4,317 $24,908 Not Implemented
MA0394 # 01 Y:1997 01 1997 CLEAR AND RENT EXISTING SPACE $262,500 $0 Implemented
MA0393 # 02 Y:1997 02 1997 REDUCE SCRAP PRODUCTION $8,750 $1,000 Implemented
MA0393 # 01 Y:1997 01 1997 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $92,750 $68,000 Implemented
MA0393 # 03 Y:1997 03 1997 INSTALL OCCUPANCY SENSORS $2,550 $356 Implemented
MA0393 # 04 Y:1997 04 1997 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $1,895 $10 Implemented
MA0393 # 05 Y:1997 05 1997 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $160 $0 Implemented
MA0393 # 06 Y:1997 06 1997 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $147 $0 Implemented
MA0274 # 04 Y:1993 04 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $585 $91 Not Implemented