Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

857

matching recommendations
Reset
SIC 3672 Printed Circuit Boards
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WI0326 # 07 Y:1998 07 1998 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,948 $740 Not Implemented
WI0326 # 08 Y:1998 08 1998 INSTALL TIMERS AND/OR THERMOSTATS $504 $400 Not Implemented
WI0326 # 09 Y:1998 09 1998 INSULATE BARE EQUIPMENT $321 $46 Not Implemented
WI0326 # 10 Y:1998 10 1998 REMOVE SLUDGE FROM TANKS ON A REGULAR BASIS $300 $0 Not Implemented
CO0417 # 01 Y:1998 01 1998 RECOVER WASTE HEAT FROM EQUIPMENT $1,680 $1,230 Implemented
CO0417 # 02 Y:1998 02 1998 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $155 $227 Implemented
CO0417 # 03 Y:1998 03 1998 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $860 $50 Implemented
CO0417 # 04 Y:1998 04 1998 TURN OFF EQUIPMENT WHEN NOT IN USE $390 $0 Implemented
CO0417 # 05 Y:1998 05 1998 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $350 $420 Implemented
CO0417 # 06 Y:1998 06 1998 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $1,560 $0 Not Implemented
CO0417 # 07 Y:1998 07 1998 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $630 $0 Not Implemented
CO0417 # 08 Y:1998 08 1998 TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY $148,000 $560 Implemented
CO0417 # 09 Y:1998 09 1998 CONDENSE OPERATION INTO ONE BUILDING $119,000 $55,330 Implemented
CO0417 # 10 Y:1998 10 1998 DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS $61,000 $0 Not Implemented
MA0402 # 01 Y:1997 01 1997 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $217,449 $140,000 Not Implemented
MA0402 # 02 Y:1997 02 1997 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $61,092 $16,597 Not Implemented
MA0402 # 03 Y:1997 03 1997 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $7,628 $6,075 Not Implemented
MA0402 # 04 Y:1997 04 1997 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $4,721 $4,925 Not Implemented
MA0402 # 05 Y:1997 05 1997 OPTIMIZE PLANT POWER FACTOR $2,577 $4,275 Not Implemented
MA0402 # 06 Y:1997 06 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,257 $200 Not Implemented
SD0177 # 01 Y:1997 01 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $6,578 $9,930 Implemented
SD0177 # 02 Y:1997 02 1997 REPLACE BOILER $19,420 $83,000 Not Implemented
SD0177 # 03 Y:1997 03 1997 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $6,154 $3,900 Not Implemented
SD0177 # 04 Y:1997 04 1997 USE OPTIMUM THICKNESS INSULATION $3,056 $2,170 Implemented
SD0177 # 05 Y:1997 05 1997 USE OPTIMUM THICKNESS INSULATION $1,916 $720 Implemented