Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
153
matching recommendationsSIC | 3672 | Printed Circuit Boards |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0120 # 05 Y:1995 | 05 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,430 | $5,990 | Implemented |
SD0120 # 06 Y:1995 | 06 | 1995 | INSTALL SPECTRAL REFLECTORS / DELAMP | $6,836 | $3,940 | Implemented |
SD0120 # 07 Y:1995 | 07 | 1995 | INSTALL OCCUPANCY SENSORS | $1,161 | $880 | Not Implemented |
SF0056 # 01 Y:1995 | 01 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $850 | $708 | Implemented |
SF0056 # 02 Y:1995 | 02 | 1995 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,130 | $4,400 | Implemented |
SF0056 # 03 Y:1995 | 03 | 1995 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $9,070 | $21,000 | Not Implemented |
SF0056 # 04 Y:1995 | 04 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,751 | $250 | Implemented |
SF0056 # 05 Y:1995 | 05 | 1995 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $87,599 | $18,750 | Implemented |
SF0056 # 06 Y:1995 | 06 | 1995 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $56,940 | $140,000 | Implemented |
SF0056 # 07 Y:1995 | 07 | 1995 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $791 | $1,680 | Implemented |
SF0056 # 08 Y:1995 | 08 | 1995 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $194,002 | $547,100 | Not Implemented |
SF0056 # 09 Y:1995 | 09 | 1995 | USE FOG NOZZLES / SPRAY RINSING INSTEAD OF IMMERSION RINSING | $29,556 | $3,040 | Implemented |
SF0056 # 10 Y:1995 | 10 | 1995 | USE COUNTER-CURRENT RINSING TO REDUCE RINSE WATER VOLUME (GRAVURE) | $1,680 | $3,546 | Implemented |
SF0056 # 11 Y:1995 | 11 | 1995 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $5,490 | $0 | Implemented |
SF0056 # 12 Y:1995 | 12 | 1995 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $177,738 | $250,240 | Not Implemented |
SD0112 # 01 Y:1995 | 01 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,149 | $450 | Implemented |
SD0112 # 02 Y:1995 | 02 | 1995 | COVER OPEN TANKS | $1,015 | $250 | Implemented |
SD0112 # 03 Y:1995 | 03 | 1995 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $1,144 | $1,600 | Implemented |
SD0112 # 04 Y:1995 | 04 | 1995 | INSULATE BARE EQUIPMENT | $2,282 | $563 | Implemented |
SD0112 # 05 Y:1995 | 05 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,168 | $6,733 | Implemented |
SD0112 # 06 Y:1995 | 06 | 1995 | INSTALL SPECTRAL REFLECTORS / DELAMP | $5,047 | $4,305 | Implemented |
SD0112 # 07 Y:1995 | 07 | 1995 | INSTALL OCCUPANCY SENSORS | $494 | $599 | Not Implemented |
SD0112 # 08 Y:1995 | 08 | 1995 | INSTALL TIMERS AND/OR THERMOSTATS | $1,306 | $849 | Implemented |
SD0112 # 09 Y:1995 | 09 | 1995 | REDUCE SOLUTION DRAG-OUT TO PREVENT SOLUTION LOSS | $730 | $250 | Implemented |
SD0112 # 10 Y:1995 | 10 | 1995 | USE IN-PROCESS RECYCLING WHENEVER POSSIBLE | $2,184 | $0 | Not Implemented |