Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
608
matching recommendationsSIC | 3674 | Semiconductors And Related Devices |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0942 # 01 Y:2016 | 01 | 2016 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,767 | $3,112 | Implemented |
OK0942 # 02 Y:2016 | 02 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $17,283 | $8,000 | Not Implemented |
OK0942 # 03 Y:2016 | 03 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $972 | $4,623 | Implemented |
OK0942 # 04 Y:2016 | 04 | 2016 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $73,902 | $31,000 | Not Implemented |
OK0942 # 05 Y:2016 | 05 | 2016 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $600 | $3,450 | Implemented |
OK0942 # 06 Y:2016 | 06 | 2016 | USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT | $469,328 | $2,302,430 | Not Implemented |
BS0066 # 01 Y:2015 | 01 | 2015 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $10,458 | $568 | Not Implemented |
BS0066 # 02 Y:2015 | 02 | 2015 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,531 | $26 | Not Implemented |
BS0066 # 03 Y:2015 | 03 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,219 | $907 | Not Implemented |
BS0066 # 04 Y:2015 | 04 | 2015 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $1,249 | $80 | Not Implemented |
BS0066 # 05 Y:2015 | 05 | 2015 | COMBINE UTILITY METERS | $258 | $253 | Not Implemented |
BS0066 # 06 Y:2015 | 06 | 2015 | PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST | $13,061 | $19,065 | Not Implemented |
BS0066 # 07 Y:2015 | 07 | 2015 | OPTIMIZE PLANT POWER FACTOR | $12,093 | $25,245 | Not Implemented |
BS0066 # 08 Y:2015 | 08 | 2015 | MINIMIZE WATER USAGE | $702 | $5,938 | Not Implemented |
UD0905 # 01 Y:2014 | 01 | 2014 | MINIMIZE CONDENSER COOLING WATER TEMPERATURE | $13,929 | $0 | Not Implemented |
UD0905 # 02 Y:2014 | 02 | 2014 | USE OPTIMUM TEMPERATURE | $5,296 | $0 | Implemented |
UD0905 # 03 Y:2014 | 03 | 2014 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,682 | $0 | Implemented |
UD0905 # 04 Y:2014 | 04 | 2014 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,046 | $0 | Implemented |
UD0905 # 05 Y:2014 | 05 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $50,533 | $188,160 | Implemented |
UD0905 # 06 Y:2014 | 06 | 2014 | INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS | $437 | $2,350 | Not Implemented |
UM0445 # 01 Y:2014 | 01 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $790 | $500 | Not Implemented |
UM0445 # 02 Y:2014 | 02 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,158 | $24,137 | Not Implemented |
UM0445 # 03 Y:2014 | 03 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $515 | $2,300 | Not Implemented |
UM0445 # 04 Y:2014 | 04 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $118 | $500 | Implemented |
SU0349 # 01 Y:2013 | 01 | 2013 | PAY BILLS ON TIME TO AVOID LATE FEES | $6,610 | $0 | Implemented |