Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
481
matching recommendationsSIC | 3679 | Electronic Components, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MAS028 # 05 Y:2012 | 05 | 2012 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $2,762 | $5,000 | Implemented |
MAS028 # 03 Y:2012 | 03 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,815 | $4,000 | Implemented |
MAS028 # 01 Y:2012 | 01 | 2012 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $37,819 | $31,800 | Implemented |
MAS025 # 05 Y:2012 | 05 | 2012 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $4,171 | $4,300 | Implemented |
SU0317 # 01 Y:2012 | 01 | 2012 | CONDENSE OPERATION INTO ONE BUILDING | $333,000 | $6,675 | Implemented |
SU0317 # 03 Y:2012 | 03 | 2012 | REDUCE VENTILATION AIR | $9,899 | $14,092 | Implemented |
SU0317 # 04 Y:2012 | 04 | 2012 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,153 | $2,179 | Implemented |
SU0317 # 05 Y:2012 | 05 | 2012 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $12,834 | $27,300 | Implemented |
BD0405 # 02 Y:2012 | 02 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,415 | $7,299 | Implemented |
BD0405 # 03 Y:2012 | 03 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,286 | $15,356 | Implemented |
BD0405 # 04 Y:2012 | 04 | 2012 | INSTALL OCCUPANCY SENSORS | $2,161 | $1,050 | Implemented |
BD0405 # 05 Y:2012 | 05 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $82 | $10 | Implemented |
BD0405 # 06 Y:2012 | 06 | 2012 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $3,704 | $40,000 | Implemented |
LE0328 # 07 Y:2011 | 07 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,383 | $2,500 | Implemented |
LE0328 # 05 Y:2011 | 05 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,369 | $15,675 | Implemented |
LE0328 # 04 Y:2011 | 04 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,650 | $3,000 | Implemented |
LE0328 # 03 Y:2011 | 03 | 2011 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $12,853 | $18,000 | Implemented |
LE0328 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,435 | $12,420 | Implemented |
UF0428 # 01 Y:2009 | 01 | 2009 | MINIMIZE USE OF RAGS THROUGH WORKER TRAINING | $1,734 | $0 | Implemented |
UF0428 # 02 Y:2009 | 02 | 2009 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,365 | $0 | Implemented |
UF0428 # 03 Y:2009 | 03 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,980 | $5,895 | Implemented |
UF0428 # 05 Y:2009 | 05 | 2009 | INSTALL OCCUPANCY SENSORS | $872 | $1,971 | Implemented |
UF0428 # 07 Y:2009 | 07 | 2009 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $4,285 | $0 | Implemented |
UF0428 # 09 Y:2009 | 09 | 2009 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $25,086 | $0 | Implemented |
LL0317 # 04 Y:2009 | 04 | 2009 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $637 | $623 | Implemented |