Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
291
matching recommendationsSIC | 3691 | Storage Batteries |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MZ0106 # 03 Y:2012 | 03 | 2012 | INSTALL OCCUPANCY SENSORS | $5,174 | $1,750 | Implemented |
MZ0106 # 02 Y:2012 | 02 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $27,548 | $31,400 | Implemented |
MZ0106 # 01 Y:2012 | 01 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $55,068 | $26,420 | Not Implemented |
IC0188 # 07 Y:2011 | 07 | 2011 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $6,453 | $0 | n/a |
IC0188 # 06 Y:2011 | 06 | 2011 | REPAIR AND ELIMINATE STEAM LEAKS | $3,582 | $690 | n/a |
IC0188 # 05 Y:2011 | 05 | 2011 | TURN OFF EQUIPMENT WHEN NOT IN USE | $422 | $0 | n/a |
IC0188 # 04 Y:2011 | 04 | 2011 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $285 | $0 | n/a |
IC0188 # 03 Y:2011 | 03 | 2011 | TURN OFF EQUIPMENT WHEN NOT IN USE | $9,096 | $0 | n/a |
IC0188 # 02 Y:2011 | 02 | 2011 | INSTALL OCCUPANCY SENSORS | $244 | $541 | Not Implemented |
IC0188 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $20,742 | $44,268 | Not Implemented |
GT0879 # 06 Y:2011 | 06 | 2011 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $339,042 | $1,340,000 | Not Implemented |
GT0879 # 05 Y:2011 | 05 | 2011 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $4,339 | $8,740 | Not Implemented |
GT0879 # 04 Y:2011 | 04 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $45,254 | $2,500 | Implemented |
GT0879 # 03 Y:2011 | 03 | 2011 | INSTALL OCCUPANCY SENSORS | $3,260 | $4,050 | Not Implemented |
GT0879 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,458 | $56,350 | Not Implemented |
GT0879 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,235 | $1 | Not Implemented |
IA0458 # 04 Y:2010 | 04 | 2010 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,520 | $2,139 | Not Implemented |
IA0458 # 08 Y:2010 | 08 | 2010 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $26,636 | $22,000 | Implemented |
IA0458 # 07 Y:2010 | 07 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $816 | $500 | Implemented |
IA0458 # 06 Y:2010 | 06 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,258 | $25 | Not Implemented |
IA0458 # 05 Y:2010 | 05 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,683 | $2,050 | Implemented |
IA0458 # 03 Y:2010 | 03 | 2010 | USE RADIANT HEATER FOR SPOT HEATING | $48,853 | $11,000 | Implemented |
IA0458 # 02 Y:2010 | 02 | 2010 | INSTALL OCCUPANCY SENSORS | $1,769 | $2,181 | Implemented |
IA0458 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,473 | $1,020 | Implemented |
LE0268 # 07 Y:2008 | 07 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,832 | $2,200 | Not Implemented |