Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
264
matching recommendationsSIC | 3699 | Electrical Equipment & Supplies, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0198 # 06 Y:2000 | 06 | 2000 | USE SOLAR HEAT TO HEAT WATER | $27,142 | $97,350 | Not Implemented |
NC0198 # 05 Y:2000 | 05 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,845 | $820 | Implemented |
NC0198 # 04 Y:2000 | 04 | 2000 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $4,264 | $0 | Implemented |
NC0198 # 03 Y:2000 | 03 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $19,308 | $41,718 | Not Implemented |
NC0198 # 02 Y:2000 | 02 | 2000 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $9,807 | $18,000 | Not Implemented |
NC0198 # 01 Y:2000 | 01 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,448 | $300 | Implemented |
UD0599 # 09 Y:2000 | 09 | 2000 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS | $872 | $500 | Not Implemented |
UD0599 # 08 Y:2000 | 08 | 2000 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $900 | $0 | Not Implemented |
UD0599 # 07 Y:2000 | 07 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,401 | $1,000 | Implemented |
UD0599 # 06 Y:2000 | 06 | 2000 | SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE | $2,628 | $0 | Implemented |
UD0599 # 05 Y:2000 | 05 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,883 | $8,852 | Not Implemented |
UD0599 # 04 Y:2000 | 04 | 2000 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $4,956 | $2,500 | Implemented |
UD0599 # 03 Y:2000 | 03 | 2000 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $4,987 | $20,000 | Implemented |
UD0599 # 02 Y:2000 | 02 | 2000 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $8,795 | $0 | Implemented |
UD0599 # 01 Y:2000 | 01 | 2000 | USE DISTILLATION, EVAPORATION TO REMOVE CONTAMINANTS | $10,974 | $10,755 | Not Implemented |
UD0588 # 01 Y:2000 | 01 | 2000 | INSTALL AN UNINTERUPTABLE POWER SUPPLY | $52,000 | $172,190 | Not Implemented |
UD0588 # 05 Y:2000 | 05 | 2000 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $1,950 | $0 | Not Implemented |
UD0588 # 04 Y:2000 | 04 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,045 | $3,000 | Not Implemented |
UD0588 # 02 Y:2000 | 02 | 2000 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $8,705 | $0 | Implemented |
UD0588 # 03 Y:2000 | 03 | 2000 | ADJUST PH FOR NEUTRALIZATION | $7,560 | $30,000 | Not Implemented |
MS0124 # 01 Y:1998 | 01 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,313 | $15,976 | Not Implemented |
MS0124 # 02 Y:1998 | 02 | 1998 | INSTALL TIMERS AND/OR THERMOSTATS | $2,507 | $944 | Implemented |
MS0124 # 03 Y:1998 | 03 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $740 | $400 | Implemented |
MS0124 # 05 Y:1998 | 05 | 1998 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $35,438 | $25,290 | Not Implemented |
MS0124 # 04 Y:1998 | 04 | 1998 | INSTALL SHELVES / RACKS TO UTILIZE UNUSED SPACE | $4,500 | $2,888 | Implemented |