Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
9,504
matching recommendationsSIC | 37 | Transportation Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NL0058 # 05 Y:2021 | 05 | 2021 | METER WASTE WATER | $2,893 | $1,106 | Not Implemented |
NL0058 # 06 Y:2021 | 06 | 2021 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,164 | $728 | Not Implemented |
NL0058 # 07 Y:2021 | 07 | 2021 | INSTALL OCCUPANCY SENSORS | $896 | $997 | Not Implemented |
UU0186 # 01 Y:2021 | 01 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,919 | $19,705 | Implemented |
UU0186 # 02 Y:2021 | 02 | 2021 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,932 | $15,000 | Not Implemented |
UU0186 # 03 Y:2021 | 03 | 2021 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $2,796 | $4,794 | Not Implemented |
UU0186 # 04 Y:2021 | 04 | 2021 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $822 | $1,645 | Implemented |
UU0186 # 05 Y:2021 | 05 | 2021 | TURN OFF EQUIPMENT WHEN NOT IN USE | $544 | $200 | Implemented |
UU0186 # 06 Y:2021 | 06 | 2021 | ADD AREA LIGHTING SWITCHES | $398 | $883 | Implemented |
UK2101 # 01 Y:2021 | 01 | 2021 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $11,574 | $6,800 | n/a |
UK2101 # 02 Y:2021 | 02 | 2021 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $68,186 | $12,380 | n/a |
UK2101 # 03 Y:2021 | 03 | 2021 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $102,514 | $43,405 | n/a |
UK2101 # 04 Y:2021 | 04 | 2021 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $8,953 | $2,145 | n/a |
UK2101 # 05 Y:2021 | 05 | 2021 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,495 | $2,215 | n/a |
UK2101 # 06 Y:2021 | 06 | 2021 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $16,094 | $170 | n/a |
UK2101 # 07 Y:2021 | 07 | 2021 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $32,159 | $7,382 | n/a |
UK2101 # 08 Y:2021 | 08 | 2021 | INSTALL OCCUPANCY SENSORS | $783 | $2,210 | n/a |
UK2101 # 09 Y:2021 | 09 | 2021 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,735 | $6,438 | n/a |
UK2101 # 10 Y:2021 | 10 | 2021 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $4,968 | $15,000 | n/a |
UK2101 # 11 Y:2021 | 11 | 2021 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,883 | $0 | n/a |
UK2101 # 12 Y:2021 | 12 | 2021 | COMBINE UTILITY METERS | $72,182 | $150,000 | n/a |
UK2101 # 13 Y:2021 | 13 | 2021 | USE SOLAR HEAT TO MAKE ELECTRICTY | $171,872 | $1,684,348 | n/a |
GT0956 # 01 Y:2021 | 01 | 2021 | TURN OFF EQUIPMENT WHEN NOT IN USE | $9,326 | $300 | Not Implemented |
GT0956 # 02 Y:2021 | 02 | 2021 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $3,116 | $451 | Implemented |
GT0956 # 03 Y:2021 | 03 | 2021 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,972 | $1,050 | Implemented |