Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,374
matching recommendationsSIC | 371 | Motor Vehicles And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0111 # 01 Y:1995 | 01 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $20,199 | $58,658 | Not Implemented |
IA0111 # 02 Y:1995 | 02 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,310 | $3,860 | Not Implemented |
IA0111 # 03 Y:1995 | 03 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,777 | $9,655 | Implemented |
IA0111 # 04 Y:1995 | 04 | 1995 | INSTALL OCCUPANCY SENSORS | $1,159 | $1,609 | Not Implemented |
IA0111 # 05 Y:1995 | 05 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,029 | $500 | Implemented |
IA0111 # 06 Y:1995 | 06 | 1995 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $11,610 | $1,200 | Not Implemented |
IA0111 # 07 Y:1995 | 07 | 1995 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $2,022 | $1,716 | Not Implemented |
IA0111 # 08 Y:1995 | 08 | 1995 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $1,672 | $8,000 | Implemented |
UM0025 # 01 Y:1995 | 01 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,153 | $1,216 | Not Implemented |
UM0025 # 02 Y:1995 | 02 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,607 | $28,762 | Not Implemented |
UM0025 # 03 Y:1995 | 03 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,494 | $3,000 | Not Implemented |
UM0025 # 04 Y:1995 | 04 | 1995 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,581 | $0 | Not Implemented |
UM0025 # 05 Y:1995 | 05 | 1995 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS | $6,138 | $1,500 | Not Implemented |
UD0458 # 01 Y:1995 | 01 | 1995 | OPTIMIZE PLANT POWER FACTOR | $11,292 | $25,000 | Implemented |
UD0458 # 02 Y:1995 | 02 | 1995 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $22,105 | $70,000 | Not Implemented |
UD0458 # 03 Y:1995 | 03 | 1995 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $23,747 | $5,000 | Implemented |
UD0458 # 04 Y:1995 | 04 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $12,040 | $30,000 | Implemented |
UD0458 # 05 Y:1995 | 05 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,553 | $23,127 | Implemented |
UD0458 # 06 Y:1995 | 06 | 1995 | KEEP LAMPS AND REFLECTORS CLEAN | $2,914 | $1,680 | Implemented |
UD0458 # 07 Y:1995 | 07 | 1995 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,344 | $0 | Not Implemented |
UD0458 # 08 Y:1995 | 08 | 1995 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $4,442 | $600 | Implemented |
UD0456 # 01 Y:1995 | 01 | 1995 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $38,300 | $70,000 | Implemented |
UD0456 # 02 Y:1995 | 02 | 1995 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $12,684 | $0 | Implemented |
UD0456 # 03 Y:1995 | 03 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $10,700 | $24,000 | Implemented |
UD0456 # 04 Y:1995 | 04 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,644 | $12,083 | Implemented |