Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
669
matching recommendationsSIC | 371 | Motor Vehicles And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0075 # 08 Y:1995 | 08 | 1995 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $3,196 | $2,194 | Not Implemented |
WV0075 # 09 Y:1995 | 09 | 1995 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $10,573 | $4,300 | Implemented |
WV0075 # 10 Y:1995 | 10 | 1995 | INSTALL AUTOMATIC STACK DAMPER | $6,023 | $725 | Not Implemented |
WV0075 # 11 Y:1995 | 11 | 1995 | INSTALL TURBULATORS | $3,340 | $700 | Not Implemented |
WV0075 # 12 Y:1995 | 12 | 1995 | INSTALL / REPAIR INSULATION ON STEAM LINES | $323 | $415 | Implemented |
WV0075 # 13 Y:1995 | 13 | 1995 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $2,415 | $480 | Implemented |
WV0075 # 14 Y:1995 | 14 | 1995 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $5,140 | $2,400 | Not Implemented |
WV0075 # 15 Y:1995 | 15 | 1995 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $18,521 | $0 | Not Implemented |
UD0458 # 01 Y:1995 | 01 | 1995 | OPTIMIZE PLANT POWER FACTOR | $11,292 | $25,000 | Implemented |
UD0458 # 02 Y:1995 | 02 | 1995 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $22,105 | $70,000 | Not Implemented |
UD0458 # 03 Y:1995 | 03 | 1995 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $23,747 | $5,000 | Implemented |
UD0458 # 04 Y:1995 | 04 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $12,040 | $30,000 | Implemented |
UD0458 # 05 Y:1995 | 05 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,553 | $23,127 | Implemented |
UD0458 # 06 Y:1995 | 06 | 1995 | KEEP LAMPS AND REFLECTORS CLEAN | $2,914 | $1,680 | Implemented |
UD0458 # 07 Y:1995 | 07 | 1995 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,344 | $0 | Not Implemented |
UD0458 # 08 Y:1995 | 08 | 1995 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $4,442 | $600 | Implemented |
UD0456 # 01 Y:1995 | 01 | 1995 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $38,300 | $70,000 | Implemented |
UD0456 # 02 Y:1995 | 02 | 1995 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $12,684 | $0 | Implemented |
UD0456 # 03 Y:1995 | 03 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $10,700 | $24,000 | Implemented |
UD0456 # 04 Y:1995 | 04 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,644 | $12,083 | Implemented |
UD0456 # 05 Y:1995 | 05 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $18,574 | $58,500 | Implemented |
UD0456 # 06 Y:1995 | 06 | 1995 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,680 | $0 | Implemented |
UD0456 # 07 Y:1995 | 07 | 1995 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,720 | $0 | Not Implemented |
UD0445 # 01 Y:1994 | 01 | 1994 | TURN OFF EQUIPMENT WHEN NOT IN USE | $262 | $0 | Implemented |
UD0445 # 02 Y:1994 | 02 | 1994 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $1,105 | $1,500 | Implemented |