Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
91
matching recommendationsSIC | 3714 | Motor Vehicle Parts And Accessories |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0429 # 03 Y:2011 | 03 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,733 | $100 | Implemented |
NC0429 # 02 Y:2011 | 02 | 2011 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $21,573 | $45,000 | Not Implemented |
NC0429 # 01 Y:2011 | 01 | 2011 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $27,312 | $0 | Not Implemented |
NC0347 # 03 Y:2006 | 03 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,895 | $3,400 | Implemented |
NC0347 # 01 Y:2006 | 01 | 2006 | DEVELOP A REPAIR/REPLACE POLICY | $6,708 | $0 | Implemented |
NC0347 # 02 Y:2006 | 02 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,347 | $100 | Implemented |
NC0347 # 06 Y:2006 | 06 | 2006 | INSULATE BARE EQUIPMENT | $95 | $165 | Not Implemented |
NC0347 # 04 Y:2006 | 04 | 2006 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $10,125 | $22,000 | Implemented |
NC0347 # 08 Y:2006 | 08 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $269 | $283 | Implemented |
NC0347 # 07 Y:2006 | 07 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,060 | $5,000 | Implemented |
NC0347 # 05 Y:2006 | 05 | 2006 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $2,239 | $5,000 | Not Implemented |
NC0297 # 01 Y:2004 | 01 | 2004 | ADJUST BURNERS FOR EFFICIENT OPERATION | $2,652 | $1,000 | Implemented |
NC0297 # 02 Y:2004 | 02 | 2004 | KEEP BOILER TUBES CLEAN | $1,635 | $800 | Implemented |
NC0297 # 03 Y:2004 | 03 | 2004 | INSULATE FEEDWATER TANK | $547 | $1,500 | Implemented |
NC0297 # 04 Y:2004 | 04 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $13,319 | $1,950 | Implemented |
NC0297 # 05 Y:2004 | 05 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $846 | $1,400 | Implemented |
NC0297 # 06 Y:2004 | 06 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,920 | $4,114 | Implemented |
NC0297 # 07 Y:2004 | 07 | 2004 | USE PHOTOCELL CONTROLS | $100 | $130 | Implemented |
NC0207 # 01 Y:2001 | 01 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $423 | $2,700 | Not Implemented |
NC0207 # 02 Y:2001 | 02 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,148 | $750 | Implemented |
NC0207 # 03 Y:2001 | 03 | 2001 | TURN OFF EQUIPMENT WHEN NOT IN USE | $16,705 | $10,000 | Implemented |
NC0207 # 04 Y:2001 | 04 | 2001 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $15,272 | $12,600 | Implemented |
NC0207 # 05 Y:2001 | 05 | 2001 | AIR CONDITION ONLY SPACE NECESSARY | $13,400 | $12,400 | Implemented |
TN0659 # 02 Y:1999 | 02 | 1999 | USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME | $15,965 | $4,260 | Not Implemented |
TN0659 # 01 Y:1999 | 01 | 1999 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $135,000 | $32,200 | Implemented |