Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
588
matching recommendationsSIC | 3724 | Aircraft Engines And Engine Parts |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0832 # 06 Y:2012 | 06 | 2012 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $7,382 | $34,962 | Not Implemented |
OK0832 # 07 Y:2012 | 07 | 2012 | SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS | $6,074 | $29,738 | Not Implemented |
OK0832 # 08 Y:2012 | 08 | 2012 | INSTALL SET-BACK TIMERS | $2,158 | $185 | Not Implemented |
OK0832 # 09 Y:2012 | 09 | 2012 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $2,579 | $1,170 | Implemented |
OK0832 # 10 Y:2012 | 10 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,669 | $696 | Not Implemented |
OK0832 # 11 Y:2012 | 11 | 2012 | OPTIMIZE PLANT POWER FACTOR | $1,632 | $8,864 | Not Implemented |
MAS026 # 01 Y:2012 | 01 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $24,352 | $59,500 | Not Implemented |
MAS026 # 02 Y:2012 | 02 | 2012 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $15,819 | $17,200 | Not Implemented |
MAS026 # 03 Y:2012 | 03 | 2012 | REDUCE VENTILATION AIR | $14,331 | $8,000 | Not Implemented |
MAS026 # 04 Y:2012 | 04 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $10,915 | $5,000 | Not Implemented |
MAS026 # 05 Y:2012 | 05 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,426 | $0 | Not Implemented |
MA0687 # 01 Y:2012 | 01 | 2012 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $50,722 | $198,500 | Not Implemented |
MA0687 # 02 Y:2012 | 02 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $10,773 | $12,025 | Not Implemented |
MA0687 # 03 Y:2012 | 03 | 2012 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $10,724 | $45,500 | Implemented |
MA0687 # 04 Y:2012 | 04 | 2012 | CONDENSE OPERATION INTO ONE BUILDING | $5,375 | $1,000 | Not Implemented |
MA0687 # 05 Y:2012 | 05 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,857 | $9,000 | Implemented |
MA0687 # 06 Y:2012 | 06 | 2012 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $3,065 | $11,500 | Implemented |
MA0687 # 07 Y:2012 | 07 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,306 | $4,500 | Not Implemented |
MA0687 # 08 Y:2012 | 08 | 2012 | INSULATE BARE EQUIPMENT | $637 | $1,250 | Not Implemented |
MA0685 # 01 Y:2011 | 01 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,634 | $7,050 | Not Implemented |
MA0685 # 02 Y:2011 | 02 | 2011 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,714 | $0 | Not Implemented |
MA0685 # 03 Y:2011 | 03 | 2011 | OPTIMIZE PLANT POWER FACTOR | $3,520 | $9,425 | Implemented |
MA0685 # 04 Y:2011 | 04 | 2011 | REDUCE VENTILATION AIR | $2,713 | $6,300 | Implemented |
MA0685 # 05 Y:2011 | 05 | 2011 | INSTALL OCCUPANCY SENSORS | $898 | $1,280 | Not Implemented |
MS0384 # 01 Y:2011 | 01 | 2011 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $6,041 | $1,900 | Not Implemented |