Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
102
matching recommendationsSIC | 3743 | Railroad Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0179 # 02 Y:1999 | 02 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $200 | $174 | Implemented |
WV0179 # 03 Y:1999 | 03 | 1999 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $455 | $270 | Implemented |
WV0179 # 05 Y:1999 | 05 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $218 | $36 | Implemented |
WV0179 # 06 Y:1999 | 06 | 1999 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,773 | $7,500 | Implemented |
WV0179 # 07 Y:1999 | 07 | 1999 | USE MINIMUM SAFE OVEN VENTILATION | $574 | $54 | Implemented |
WV0179 # 08 Y:1999 | 08 | 1999 | USE OPTIMUM THICKNESS INSULATION | $1,109 | $675 | Implemented |
WV0179 # 09 Y:1999 | 09 | 1999 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $834 | $1,308 | Implemented |
WV0179 # 10 Y:1999 | 10 | 1999 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $54,372 | $16,000 | Implemented |
WV0179 # 12 Y:1999 | 12 | 1999 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $47 | $60 | Implemented |
KU0492 # 02 Y:1998 | 02 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,750 | $700 | Implemented |
KU0492 # 05 Y:1998 | 05 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $400 | $1,000 | Implemented |
KU0492 # 08 Y:1998 | 08 | 1998 | PURCHASE HIGH MATERIALS IN RETURNABLE BULK CONTAINERS | $1,510 | $940 | Implemented |
KU0492 # 09 Y:1998 | 09 | 1998 | PURCHASE EQUIPMENT INSTEAD OF LEASING | $4,200 | $12,000 | Implemented |
MO0213 # 01 Y:1997 | 01 | 1997 | CROSS-TRAIN PERSONNEL TO AVOID LOST TIME | $12,142 | $20,000 | Implemented |
MO0213 # 02 Y:1997 | 02 | 1997 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $8,250 | $10,000 | Implemented |
MO0213 # 04 Y:1997 | 04 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,904 | $1,046 | Implemented |
MO0213 # 06 Y:1997 | 06 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,326 | $3,383 | Implemented |
MO0213 # 07 Y:1997 | 07 | 1997 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,372 | $80 | Implemented |
MO0213 # 10 Y:1997 | 10 | 1997 | UPGRADE OBSOLETE EQUIPMENT | $4,950 | $6,000 | Implemented |
NC0118 # 01 Y:1997 | 01 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,752 | $690 | Implemented |
NC0118 # 05 Y:1997 | 05 | 1997 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $27,676 | $0 | Implemented |
KU0472 # 01 Y:1997 | 01 | 1997 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $920 | $100 | Implemented |
KU0472 # 04 Y:1997 | 04 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $410 | $310 | Implemented |
KU0472 # 05 Y:1997 | 05 | 1997 | USE SYNTHETIC LUBRICANT | $320 | $310 | Implemented |
KU0472 # 06 Y:1997 | 06 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $260 | $480 | Implemented |