Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
54
matching recommendationsSIC | 3764 | Space Propulsion Units And Parts |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IP0152 # 01 Y:2021 | 01 | 2021 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $236 | $35 | Not Implemented |
IP0152 # 02 Y:2021 | 02 | 2021 | INSTALL OCCUPANCY SENSORS | $80 | $97 | Not Implemented |
IP0152 # 03 Y:2021 | 03 | 2021 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $22,427 | $10,500 | Not Implemented |
IP0152 # 04 Y:2021 | 04 | 2021 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,039 | $1,254 | Not Implemented |
IP0152 # 05 Y:2021 | 05 | 2021 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $268 | $867 | Not Implemented |
AS0476 # 02 Y:2019 | 02 | 2019 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $379,615 | $78,024 | Not Implemented |
AS0476 # 03 Y:2019 | 03 | 2019 | OPTIMIZE PLANT POWER FACTOR | $65,373 | $17,381 | Not Implemented |
AS0476 # 04 Y:2019 | 04 | 2019 | RECOVER AND REUSE COOLING WATER | $14,698 | $7,484 | Not Implemented |
AS0476 # 01 Y:2019 | 01 | 2019 | INSTALL WIND POWERED ELECTRIC GENERATOR | $924,031 | $7,925,140 | Not Implemented |
LE0326 # 05 Y:2011 | 05 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,890 | $10,580 | Implemented |
LE0326 # 11 Y:2011 | 11 | 2011 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $1,230 | $35,000 | Implemented |
LE0326 # 10 Y:2011 | 10 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,381 | $2,000 | Not Implemented |
LE0326 # 09 Y:2011 | 09 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,818 | $1,000 | Implemented |
LE0326 # 08 Y:2011 | 08 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,956 | $25 | Implemented |
LE0326 # 07 Y:2011 | 07 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,949 | $500 | Not Implemented |
LE0326 # 06 Y:2011 | 06 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,255 | $1,000 | Implemented |
LE0326 # 04 Y:2011 | 04 | 2011 | INSTALL TIMERS AND/OR THERMOSTATS | $6,020 | $95 | Implemented |
LE0326 # 03 Y:2011 | 03 | 2011 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $9,313 | $108 | Implemented |
LE0326 # 02 Y:2011 | 02 | 2011 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $10,236 | $51,475 | Implemented |
LE0326 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,373 | $21,660 | Implemented |
UU0112 # 01 Y:2006 | 01 | 2006 | TURN OFF EQUIPMENT WHEN NOT IN USE | $0 | $0 | Not Implemented |
UU0112 # 02 Y:2006 | 02 | 2006 | REPAIR OR REPLACE STEAM TRAPS | $121,540 | $8,720 | Not Implemented |
UU0112 # 03 Y:2006 | 03 | 2006 | CLOSE OFF UNNEEDED STEAM LINES | $140,530 | $250,000 | Not Implemented |
UU0112 # 05 Y:2006 | 05 | 2006 | TURN OFF STEAM / HOT WATER LINES LEADING TO SPACE HEATING UNITS | $65,810 | $442,960 | Not Implemented |
UU0112 # 04 Y:2006 | 04 | 2006 | INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) | $69,680 | $200,000 | Not Implemented |