Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,872
matching recommendationsSIC | 38 | Instruments And Related Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0189 # 05 Y:2004 | 05 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $293 | $0 | Implemented |
SD0341 # 02 Y:2004 | 02 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $570 | $200 | Implemented |
SD0341 # 04 Y:2004 | 04 | 2004 | INSTALL OCCUPANCY SENSORS | $965 | $400 | Implemented |
AM0463 # 01 Y:2004 | 01 | 2004 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $23,300 | $19,700 | Implemented |
AM0463 # 02 Y:2004 | 02 | 2004 | OPTIMIZE PLANT POWER FACTOR | $18,200 | $16,600 | Implemented |
AM0463 # 04 Y:2004 | 04 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $3,100 | $0 | Implemented |
AM0463 # 05 Y:2004 | 05 | 2004 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $1,475 | $0 | Implemented |
AM0463 # 07 Y:2004 | 07 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,450 | $730 | Implemented |
AM0463 # 08 Y:2004 | 08 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,030 | $400 | Implemented |
CO0544 # 01 Y:2004 | 01 | 2004 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $152,970 | $140,000 | Implemented |
CO0544 # 02 Y:2004 | 02 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,600 | $300 | Implemented |
CO0544 # 05 Y:2004 | 05 | 2004 | INSULATE BARE EQUIPMENT | $310 | $250 | Implemented |
SD0339 # 01 Y:2004 | 01 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $15,112 | $320 | Implemented |
SD0339 # 03 Y:2004 | 03 | 2004 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $3,831 | $0 | Implemented |
LM0071 # 03 Y:2004 | 03 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $8,163 | $945 | Implemented |
LM0071 # 04 Y:2004 | 04 | 2004 | INSTALL OCCUPANCY SENSORS | $1,330 | $1,200 | Implemented |
LM0071 # 05 Y:2004 | 05 | 2004 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $7,879 | $0 | Implemented |
LM0071 # 07 Y:2004 | 07 | 2004 | MODIFY CURRENT INCENTIVE PROGRAM | $3,000 | $300 | Implemented |
LM0071 # 10 Y:2004 | 10 | 2004 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $84,322 | $100,000 | Implemented |
OK0668 # 02 Y:2003 | 02 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $25,013 | $38,456 | Implemented |
OK0668 # 03 Y:2003 | 03 | 2003 | INSTALL OCCUPANCY SENSORS | $6,113 | $1,885 | Implemented |
OK0668 # 04 Y:2003 | 04 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,597 | $0 | Implemented |
OK0668 # 05 Y:2003 | 05 | 2003 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $67,238 | $0 | Implemented |
OK0668 # 06 Y:2003 | 06 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $21,821 | $1,125 | Implemented |
OK0668 # 09 Y:2003 | 09 | 2003 | INSULATE BARE EQUIPMENT | $1,369 | $1,455 | Implemented |