Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
761
matching recommendationsSIC | 382 | Measuring And Controlling Devices |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0485 # 02 Y:1997 | 02 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $560 | $660 | Implemented |
KU0485 # 03 Y:1997 | 03 | 1997 | INSULATE BARE EQUIPMENT | $470 | $300 | Implemented |
KU0485 # 06 Y:1997 | 06 | 1997 | RECOVER AND REUSE COOLING WATER | $1,080 | $1,180 | Implemented |
KU0485 # 07 Y:1997 | 07 | 1997 | METER WASTE WATER | $230 | $100 | Implemented |
UF0186 # 02 Y:1997 | 02 | 1997 | INSTALL OCCUPANCY SENSORS | $2,264 | $1,984 | Implemented |
UF0186 # 03 Y:1997 | 03 | 1997 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $313 | $133 | Implemented |
UF0186 # 04 Y:1997 | 04 | 1997 | USE OPTIMUM THICKNESS INSULATION | $15,189 | $35,749 | Implemented |
UF0186 # 06 Y:1997 | 06 | 1997 | COVER CONTAINERS TO MINIMIZE EVAPORATIVE LOSSES | $2,700 | $5,800 | Implemented |
CO0393 # 01 Y:1997 | 01 | 1997 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $4,000 | $1,170 | Implemented |
CO0393 # 02 Y:1997 | 02 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,200 | $240 | Implemented |
CO0393 # 03 Y:1997 | 03 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $358 | $403 | Implemented |
CO0393 # 05 Y:1997 | 05 | 1997 | USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES | $201,090 | $3,970 | Implemented |
CO0393 # 06 Y:1997 | 06 | 1997 | COVER CONTAINERS TO MINIMIZE EVAPORATIVE LOSSES | $9,120 | $10,000 | Implemented |
CO0393 # 07 Y:1997 | 07 | 1997 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $400 | $0 | Implemented |
CO0393 # 08 Y:1997 | 08 | 1997 | REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL | $113,220 | $25,000 | Implemented |
WV0124 # 01 Y:1997 | 01 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,851 | $361 | Implemented |
WV0124 # 02 Y:1997 | 02 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,835 | $1,740 | Implemented |
WV0124 # 03 Y:1997 | 03 | 1997 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $391 | $1,080 | Implemented |
WV0124 # 05 Y:1997 | 05 | 1997 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $5,413 | $0 | Implemented |
WV0124 # 06 Y:1997 | 06 | 1997 | REDUCE VENTILATION AIR | $7,818 | $6,200 | Implemented |
WV0124 # 12 Y:1997 | 12 | 1997 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $7,143 | $1,570 | Implemented |
CO0388 # 02 Y:1997 | 02 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $970 | $400 | Implemented |
CO0388 # 03 Y:1997 | 03 | 1997 | RECOVER WASTE HEAT FROM EQUIPMENT | $390 | $930 | Implemented |
CO0388 # 04 Y:1997 | 04 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $390 | $330 | Implemented |
CO0388 # 09 Y:1997 | 09 | 1997 | ELIMINATE/REDUCE REDUNDANT INSPECTIONS | $5,910 | $14,000 | Implemented |