Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
761
matching recommendationsSIC | 382 | Measuring And Controlling Devices |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0868 # 07 Y:2013 | 07 | 2013 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $7,022 | $1,140 | Implemented |
OK0868 # 09 Y:2013 | 09 | 2013 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $287 | $456 | Implemented |
OK0868 # 11 Y:2013 | 11 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,457 | $13,371 | Implemented |
OK0868 # 13 Y:2013 | 13 | 2013 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $33,598 | $0 | Implemented |
SF0441 # 01 Y:2013 | 01 | 2013 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $27,444 | $0 | Implemented |
SF0441 # 02 Y:2013 | 02 | 2013 | INSTALL SPECTRAL REFLECTORS / DELAMP | $651 | $420 | Implemented |
LE0367 # 02 Y:2013 | 02 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $18,213 | $15,750 | Implemented |
LE0367 # 03 Y:2013 | 03 | 2013 | INSTALL TIMERS AND/OR THERMOSTATS | $1,711 | $0 | Implemented |
LE0367 # 05 Y:2013 | 05 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,516 | $1,350 | Implemented |
MA0708 # 03 Y:2013 | 03 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,140 | $400 | Implemented |
MA0708 # 04 Y:2013 | 04 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,828 | $3,200 | Implemented |
MI0237 # 01 Y:2013 | 01 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $22,474 | $10,160 | Implemented |
MI0237 # 02 Y:2013 | 02 | 2013 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $6,857 | $80 | Implemented |
MI0237 # 04 Y:2013 | 04 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,086 | $80 | Implemented |
MI0237 # 05 Y:2013 | 05 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,565 | $1,660 | Implemented |
MI0237 # 06 Y:2013 | 06 | 2013 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,104 | $2,406 | Implemented |
MI0237 # 07 Y:2013 | 07 | 2013 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $1,045 | $40 | Implemented |
MI0237 # 08 Y:2013 | 08 | 2013 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $714 | $205 | Implemented |
MI0237 # 10 Y:2013 | 10 | 2013 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $396 | $1,880 | Implemented |
MA0704 # 04 Y:2013 | 04 | 2013 | REDUCE VENTILATION AIR | $2,055 | $5,900 | Implemented |
SD0460 # 01 Y:2013 | 01 | 2013 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $50,132 | $152,300 | Implemented |
SD0460 # 03 Y:2013 | 03 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $11,357 | $1,000 | Implemented |
SD0460 # 04 Y:2013 | 04 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,875 | $900 | Implemented |
SD0460 # 07 Y:2013 | 07 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,515 | $3,212 | Implemented |
SD0460 # 08 Y:2013 | 08 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,570 | $200 | Implemented |