Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
141
matching recommendationsSIC | 3824 | Fluid Meters And Counting Devices |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0591 # 08 Y:2020 | 08 | 2020 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $834 | $50 | Not Implemented |
WV0591 # 04 Y:2020 | 04 | 2020 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,574 | $1,468 | Implemented |
WV0591 # 06 Y:2020 | 06 | 2020 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,896 | $1,770 | Not Implemented |
CL1905 # 03 Y:2019 | 03 | 2019 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,441 | $0 | Implemented |
CL1905 # 01 Y:2019 | 01 | 2019 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $4,261 | $6,500 | Implemented |
CL1905 # 04 Y:2019 | 04 | 2019 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,586 | $1,600 | Implemented |
CL1905 # 05 Y:2019 | 05 | 2019 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $139 | $900 | Implemented |
CL1905 # 06 Y:2019 | 06 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,489 | $13,085 | Implemented |
CL1905 # 02 Y:2019 | 02 | 2019 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $918 | $2,080 | Implemented |
WM0078 # 06 Y:2015 | 06 | 2015 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $4,749 | $8,000 | Not Implemented |
WM0078 # 05 Y:2015 | 05 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,459 | $11,985 | Not Implemented |
WM0078 # 07 Y:2015 | 07 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,708 | $400 | Not Implemented |
WM0078 # 03 Y:2015 | 03 | 2015 | OPTIMIZE PLANT POWER FACTOR | $11,162 | $18,000 | Not Implemented |
WM0078 # 01 Y:2015 | 01 | 2015 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $31,723 | $105,982 | Not Implemented |
WM0078 # 04 Y:2015 | 04 | 2015 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $10,083 | $3,000 | Not Implemented |
WM0078 # 11 Y:2015 | 11 | 2015 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,156 | $300 | Not Implemented |
WM0078 # 02 Y:2015 | 02 | 2015 | USE SYNTHETIC LUBRICANT | $14,981 | $4,505 | Not Implemented |
WM0078 # 10 Y:2015 | 10 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,824 | $1,300 | Not Implemented |
WM0078 # 08 Y:2015 | 08 | 2015 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,724 | $2,584 | Not Implemented |
WM0078 # 09 Y:2015 | 09 | 2015 | USE PHOTOCELL CONTROLS | $2,082 | $2,816 | Not Implemented |
WM0078 # 12 Y:2015 | 12 | 2015 | INSTALL OCCUPANCY SENSORS | $1,006 | $1,500 | Not Implemented |
OK0876 # 03 Y:2014 | 03 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,306 | $530 | Not Implemented |
OK0876 # 02 Y:2014 | 02 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $681 | $1,600 | Not Implemented |
OK0876 # 07 Y:2014 | 07 | 2014 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $1,400 | $30 | Not Implemented |
OK0876 # 08 Y:2014 | 08 | 2014 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $41,800 | $54,000 | Not Implemented |