Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
100
matching recommendationsSIC | 3827 | Optical Instruments And Lenses |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0327 # 04 Y:2012 | 04 | 2012 | REDUCE VENTILATION AIR | $2,247 | $4,271 | Implemented |
LL0355 # 04 Y:2011 | 04 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,751 | $11,200 | Implemented |
LL0355 # 03 Y:2011 | 03 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,642 | $1,680 | Implemented |
LL0355 # 02 Y:2011 | 02 | 2011 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $7,278 | $4,106 | Implemented |
LL0355 # 01 Y:2011 | 01 | 2011 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $121,680 | $22,440 | Implemented |
MA0661 # 03 Y:2010 | 03 | 2010 | REDUCE VENTILATION AIR | $31,319 | $17,008 | Implemented |
MA0661 # 06 Y:2010 | 06 | 2010 | AIR CONDITION ONLY SPACE NECESSARY | $2,526 | $11,040 | Implemented |
MA0661 # 05 Y:2010 | 05 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $232 | $260 | Implemented |
MA0661 # 04 Y:2010 | 04 | 2010 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $707 | $110 | Implemented |
MA0661 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $562 | $588 | Implemented |
MA0660 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,403 | $9,546 | Implemented |
MA0660 # 03 Y:2010 | 03 | 2010 | TURN OFF EQUIPMENT WHEN NOT IN USE | $58,587 | $0 | Implemented |
MA0660 # 05 Y:2010 | 05 | 2010 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $23,123 | $0 | Implemented |
SU0288 # 05 Y:2010 | 05 | 2010 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $161 | $729 | Implemented |
SU0288 # 02 Y:2010 | 02 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,730 | $710 | Implemented |
SU0288 # 01 Y:2010 | 01 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,422 | $0 | Implemented |
SU0288 # 03 Y:2010 | 03 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,392 | $2,257 | Implemented |
SU0288 # 04 Y:2010 | 04 | 2010 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $50,239 | $171,000 | Implemented |
MA0652 # 02 Y:2009 | 02 | 2009 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $10,132 | $23,474 | Implemented |
LE0210 # 04 Y:2005 | 04 | 2005 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,330 | $4,866 | Implemented |
LE0210 # 06 Y:2005 | 06 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $255 | $80 | Implemented |
LE0210 # 03 Y:2005 | 03 | 2005 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,616 | $2,000 | Implemented |
LE0210 # 02 Y:2005 | 02 | 2005 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,088 | $750 | Implemented |
SU0196 # 01 Y:2004 | 01 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $4,000 | $0 | Implemented |
SU0196 # 02 Y:2004 | 02 | 2004 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,956 | $0 | Implemented |