Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
629
matching recommendationsSIC | 399 | Miscellaneous Manufactures |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0087 # 03 Y:2012 | 03 | 2012 | USE RADIANT HEATER FOR SPOT HEATING | $410,000 | $1,200,000 | Implemented |
DL0087 # 04 Y:2012 | 04 | 2012 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $20,000 | $78,000 | Implemented |
DL0087 # 05 Y:2012 | 05 | 2012 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $11,900 | $14,000 | Implemented |
DL0087 # 08 Y:2012 | 08 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,200 | $5,400 | Implemented |
MAS017 # 01 Y:2012 | 01 | 2012 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $34,566 | $10,000 | Implemented |
MAS016 # 01 Y:2012 | 01 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $21,510 | $5,600 | Implemented |
MAS016 # 03 Y:2012 | 03 | 2012 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $9,910 | $0 | Implemented |
MI0201 # 02 Y:2011 | 02 | 2011 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $27,894 | $2,000 | Implemented |
MI0201 # 03 Y:2011 | 03 | 2011 | TURN OFF EQUIPMENT WHEN NOT IN USE | $18,870 | $7,920 | Implemented |
MI0201 # 07 Y:2011 | 07 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,900 | $40 | Implemented |
MI0201 # 08 Y:2011 | 08 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $4,894 | $2,200 | Implemented |
SD0503 # 01 Y:2010 | 01 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $33,987 | $2,250 | Implemented |
SD0503 # 02 Y:2010 | 02 | 2010 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $28,203 | $56,758 | Implemented |
SD0503 # 03 Y:2010 | 03 | 2010 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $24,981 | $0 | Implemented |
SD0503 # 04 Y:2010 | 04 | 2010 | INSTALL SKYLIGHTS | $7,467 | $22,980 | Implemented |
IA0454 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,680 | $5,214 | Implemented |
IA0454 # 02 Y:2010 | 02 | 2010 | INSTALL OCCUPANCY SENSORS | $1,365 | $1,560 | Implemented |
IA0454 # 05 Y:2010 | 05 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,229 | $300 | Implemented |
IA0454 # 06 Y:2010 | 06 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $980 | $400 | Implemented |
IA0454 # 07 Y:2010 | 07 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,152 | $300 | Implemented |
IA0454 # 08 Y:2010 | 08 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $201 | $150 | Implemented |
OK0793 # 01 Y:2010 | 01 | 2010 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $88,705 | $104,400 | Implemented |
OK0793 # 06 Y:2010 | 06 | 2010 | INSTALL OCCUPANCY SENSORS | $8,717 | $17,813 | Implemented |
OK0793 # 12 Y:2010 | 12 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $13,071 | $995 | Implemented |
OK0793 # 13 Y:2010 | 13 | 2010 | UPGRADE CONTROLS ON COMPRESSORS | $27,218 | $30,300 | Implemented |