Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
157
matching recommendationsSIC | 495 | Sanitary Services |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WM0114 # 06 Y:2017 | 06 | 2017 | INSTALL OCCUPANCY SENSORS | $3,167 | $1,660 | Not Implemented |
WM0114 # 07 Y:2017 | 07 | 2017 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,956 | $0 | Implemented |
WM0114 # 08 Y:2017 | 08 | 2017 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,082 | $3,200 | Implemented |
WM0114 # 09 Y:2017 | 09 | 2017 | USE PHOTOCELL CONTROLS | $615 | $73 | Not Implemented |
WM0112 # 01 Y:2017 | 01 | 2017 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $47,713 | $150,000 | Implemented |
WM0112 # 02 Y:2017 | 02 | 2017 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $16,077 | $29,868 | Not Implemented |
WM0112 # 03 Y:2017 | 03 | 2017 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $12,320 | $0 | Implemented |
WM0112 # 04 Y:2017 | 04 | 2017 | INSTALL OCCUPANCY SENSORS | $10,947 | $460 | Implemented |
WM0112 # 05 Y:2017 | 05 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,535 | $3,553 | Implemented |
WM0112 # 06 Y:2017 | 06 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,480 | $14,400 | Implemented |
WM0112 # 07 Y:2017 | 07 | 2017 | USE PHOTOCELL CONTROLS | $4,426 | $1,430 | Not Implemented |
WM0111 # 01 Y:2017 | 01 | 2017 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $135,557 | $350,000 | Not Implemented |
WM0111 # 02 Y:2017 | 02 | 2017 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $38,256 | $90,000 | Not Implemented |
WM0111 # 03 Y:2017 | 03 | 2017 | USE SYNTHETIC LUBRICANT | $30,600 | $7,500 | Not Implemented |
WM0111 # 04 Y:2017 | 04 | 2017 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $24,084 | $45,000 | Not Implemented |
WM0111 # 05 Y:2017 | 05 | 2017 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $23,424 | $56,250 | Not Implemented |
WM0111 # 06 Y:2017 | 06 | 2017 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $16,506 | $73,860 | Not Implemented |
WM0109 # 01 Y:2017 | 01 | 2017 | RECOVER AND REUSE WASTE MATERIAL | $282,127 | $836,828 | Not Implemented |
WM0109 # 02 Y:2017 | 02 | 2017 | USE SOLAR HEAT TO MAKE ELECTRICTY | $27,888 | $228,151 | Not Implemented |
WM0109 # 03 Y:2017 | 03 | 2017 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $14,544 | $42,400 | Not Implemented |
WM0109 # 04 Y:2017 | 04 | 2017 | USE RADIANT HEATER FOR SPOT HEATING | $3,705 | $6,960 | Not Implemented |
WM0109 # 05 Y:2017 | 05 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,624 | $1,590 | Not Implemented |
WM0109 # 06 Y:2017 | 06 | 2017 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,520 | $0 | Implemented |
WM0109 # 07 Y:2017 | 07 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,182 | $1,400 | Not Implemented |
WM0109 # 08 Y:2017 | 08 | 2017 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $817 | $1,224 | Not Implemented |